ISO/IEC 6523 Data interchange-
Structure for the identification of organizations

 

Numerical list of all ICDs that have been issued.

 

 

This list is maintained by

British Standards Institution

As the ISO/IEC 6523 Registration Authority

 

Contact

Anna Wadsworth

Anna_Wadsworth@bsi.org.uk

 

 

 

5 April 2000

 

 

 

ICD Code

Name of Coding System

0001

not assigned

0002

System Information et Repertoire des Entreprise et des Etablissements : SIRENE

0003

Codification Numerique des Etablissments Financiers En Belgique

0004

NBS/OSI NETWORK

0005

USA FED GOV OSI NETWORK

0006

USA DOD OSI NETWORK

0007

Organisationsnummer

0008

LE NUMERO NATIONAL

0009

SIRET-CODE

0010

Organizational Identifiers for Structured Names under ISO 9541 Part 2

0011

International Code Designator for the Identification of OSI-based, Amateur Radio Organizations, Network Objects and Application Services.

0012

European Computer Manufacturers Association : ECMA

0013

VSA FTP CODE (FTP = File Transfer Protocol)

0014

NIST/OSI Implememts' Workshop

0015

Electronic Data Interchange : EDI

0016

EWOS Object Identifiers

0017

COMMON LANGUAGE

0018

SNA/OSI Network

0019

Air Transport Industry Services Communications Network

0020

European Laboratory for Particle Physics: CERN

0021

SOCIETY FOR WORLDWIDE INTERBANK FINANCIAL TELECOMMUNICATION S.W.I.F.T.

0022

OSF Distributed Computing Object Identification

0023

Nordic University and Research Network: NORDUnet

0024

Digital Equipment Corporation: DEC

0025

OSI ASIA-OCEANIA WORKSHOP

0026

NATO ISO6523 ICDE coding scheme

0027

Aeronautical Telecommunications Network (ATN)

0028

International Standard ISO 6523

0029

The All-Union Classifier of Enterprises and Organisations

0030

AT&T/OSI Network

0031

EDI Partner Identification Code

0032

Telecom Australia

0033

S G W OSI Internetwork

0034

Reuter Open Address Standard

0035

ISO 6523 – ICD

0036

TeleTrust Object Identifiers

0037

LY-tunnus

0038

The Australian GOSIP Network

0039

The OZ DOD OSI Network

0040

Unilever Group Companies

0041

Citicorp Global Information Network

0042

DBP Telekom Object Identifiers

0043

HydroNETT

0044

Thai Industrial Standards Institute (TISI)

0045

ICI Company Identification System

0046

FUNLOC

0047

BULL ODI/DSA/UNIX Network

0048

OSINZ

0049

Auckland Area Health

0050

Firmenich

0051

AGFA-DIS

0052

Society of Motion Picture and Television Engineers (SMPTE)

0053

Migros_Network M_NETOPZ

0054

ISO6523 – ICDPCR

0055

Energy Net

0056

Nokia Object Identifiers (NOI)

0057

Saint Gobain

0058

Siemens Corporate Network

0059

DANZNET

0060

Data Universal Numbering System (D-U-N-S Number)

0061

SOFFEX OSI

0062

Unisource Business Networks

0063

AscomOSINet

0064

UTC: Uniforme Transport Code

0065

SOLVAY OSI CODING

0066

Roche Corporate Network

0067

ZellwegerOSINet

0068

Intel Corporation OSI

0069

SITA Object Identifier Tree

0070

Daimler Benz Corporate Network

0071

LEGO /OSI NETWORK

0072

NAVISTAR/OSI Network

0073

ICD Formatted ATM address

0074

ARINC

0075

Alcanet/Alcatel-Alsthom Corporate Network

0076

Sistema Italiano di Identificazione di ogetti gestito da UNINFO

0077

Sistema Italiano di Indirizzamento di Reti OSI Gestito da UNINFO

0078

Mitel terminal or switching equipment

0079

ATM Forum

0080

UK National Health Service Scheme (EDIRA compliant)

0081

International NSAP

0082

Norwegian Telecommunications Authority's, NTA'S, EDI, identifier scheme (EDIRA compliant)

0083

Advanced Telecommunications Modules Limited Corporate Network

0084

Athens Chamber of Commerce & Industry Scheme(EDIRA compliant)

0085

Swiss Chambers of Commerce (Scheme) (EDIRA compliant)

0086

United States Council for International Business (USCIB) Scheme(EDIRA compliant)

0087

National Federation of Chambers of Commerce & Industry of Belgium Scheme (EDIRA compliant)

0088

EAN Location Code

0089

The Association of British Chambers of Commerce Ltd. Scheme (EDIRA compliant)

0090

Internet IP addressing - ISO 6523 ICD encoding

0091

Cisco Sysytems / OSI Network

0092

Not to be assigned (see additional comments)

0093

Revenue Canada Business Number Registration (EDIRA compliant)

0094

DEUTSCHER INDUSTRIE- UND HANDELSTAG (DIHT) Scheme (EDIRA compliant)

0095

Hewlett - Packard Company Internal AM Network

0096

DANISH CHAMBER OF COMMERCE Scheme (EDIRA compliant)

0097

FTI - Ediforum Italia (EDIRA compliant)

0098

CHAMBER OF COMMERCE TEL AVIV-JAFFA Scheme (EDIRA compliant)

0099

Siemens Supervisory Systems Network

0100

PNG_ICD Scheme

0101

South African Code Allocation

0102

HEAG

0103

(Reserved for later allocation)

0104

BT - ICD Coding System

0105

Portuguese Chamber of Commerce and Industry Scheme (EDIRA compliant)

0106

Vereniging van Kamers van Koophandel en Fabrieken in Nederland(Association of Chambers of Commerce and Industry in the Netherlands) Scheme (EDIRA compliant)

0107

Association of Swedish Chambers of Commerce and Industry Scheme (EDIRA compliant)

0108

Australian Chambers of Commerce and Industry Scheme (EDIRA compliant)

0109

BellSouth ICD AESA (ATM End System Address)

0110

Bell Atlantic

0111

Object Identifiers

0112

ISO register for Standards producing Organizations

0113

OriginNet

0114

Check Point Software Technologies

0115

Pacific Bell Data Communications Network

0116

PSS Object Identifiers

0117

STENTOR-ICD CODING SYSTEM

0118

ATM-Network ZN’96

0119

MCI / OSI Network

0120

Advantis

0121

Affable Software Data Interchange Codes

0122

BB-DATA GmbH

0123

BASF Company ATM-Network

0124

IOTA- Identifiers for Organizations for Telecommunications Addressing using the ICD system format defined in ISO/IEC 8348

0125

Henkel Corporate Network (H-Net)

0126

GTE/OSI Network

0127

Dresdner Bank Corporate Network

0128

BNCR (Telekurs Banken Clearing Number)

0129

BPI (Telekurs Business Partner Identification)

0130

Directorates of the European Commission

0131

Code for the Identification of National Organizations

0132

Certicom Object Identifiers

0133

TC68 OID

0134

Infonet Services Corporation

0135

SIA Object Identifiers

0136

Cable & Wireless Global ATM End-System Address Plan

0137

Global AESA scheme

0138

France Telecom ATM End System Address Plan

0139

Savvis Communications AESA

0140

Toshiba Organizations, Partners, And Suppliers’ (TOPAS) Code

0141

NATO Commercial and Government Entity system

0142

SECETI Object Identifiers

 

 

 

 

0001

Registration Information

ICD:

0001

Name of coding system:

not assigned

Name & address of issuing organisation:

 

Structure of code:

 

Display Requirements:

 

Description of organizations covered by the coding system:

 

Notes on use of the code:

 

Sponsoring authority:

 

Date of issue of ICD:

 

Additional comments:

 

 

 

 

0002

Registration Information

ICD:

0002

Name of coding system:

System Information et Repertoire des Entreprise et des Etablissements : SIRENE

Name & address of issuing organisation:

Institut National de la Statistique et des Etudes
Economiques, (I.N.S.E.E.)
Departement des Repertoires,
18, Bd Adolphe Pinard,
75675 PARIS Cedex 14

Tel: 540 1212
Tlx:204924 INSEE F

Structure of code:

1) Number of characters : 9 characters ("SIREN")
14 " 9+5 ("SIRET")
The 9 character number designates an organization
The 14 character number designates a specific establishment of the organization designated by the first 9 characters.

2) Check digits : 9th & 14th character respectively

Display Requirements:

The 9 figure code number (SIREN) is written in groups of 3 characters. Example: 784 301 772

The 14 figure code number is written in 3 groups of 3 characters and a single group of 5. Example: 784 301 772 00025

Description of organizations covered by the coding system:

Enterprises; (individual enterprises or companies) in the field of agriculture, industry, trade, services, Associations; Authorities, regional authorities and public establishments active in France. Number of units covered: approximately 3,300,000.

Notes on use of the code:

The Sirene number is used in France mainly for the official registration in the Trade Register and as the only number used between authorities an organizations, and between authorities when dealing with data interchange on organizations.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

January 1986

Additional comments:

None

 

 

 

0003

Registration Information

ICD:

0003

Name of coding system:

Codification Numerique des Etablissments Financiers En Belgique

Name & address of issuing organisation:

Association Belge des Banques
rue Ravenstein 36, Bte 5
1000 BRUXELLES

Tel: 02 512 5868

Structure of code:

  1. 3 numeric digits
  2. None

Display Requirements:

In one group of three

Description of organizations covered by the coding system:

All financial institutions in Belgium.

Notes on use of the code:

Many financial institutions have more than one code number, e.g to indicate each branch individually. The codes can be reallocated over the time (mostly in the case where a financial institution terminates its activity). Some code numbers are currently unused. Code numbers 990 through 999 are reserved.

Sponsoring authority:

Organization for Data Exchange by Tele Transmission in Europe : ODETTE

Date of issue of ICD:

February 1986

Additional comments:

None

 

 

 

0004

Registration Information

ICD:

0004

Name of coding system:

NBS/OSI NETWORK

Name & address of issuing organisation:

National Bureau of Standards
Bldg 225 Room B151
Gaithersburg MD, 20899
USA

Tel: 301 975 2833
Tlx: 197674 NBS UT

Structure of code:

  1. 0004 OSINET Open System Interconnection Network
  2. No check digits are needed as the whole message has a checking mechanism.

Display Requirements:

None except that all fields are left justified.

Description of organizations covered by the coding system:

NBS will assign a sub value to any company or organizations that participates in the OSINET. The covered by program encompasses companies in the US as well as the code Europe and Asia.

Notes on use of the code:

The ICD code forms the initial part of the OSI network addressing and naming tree as depicted in Addendum 2 to ISO 8348.

Sponsoring authority:

American National Standards Institute : ANSI

Date of issue of ICD:

February 1988

Additional comments:

None

 

 

 

0005

Registration Information

ICD:

0005

Name of coding system:

USA FED GOV OSI NETWORK

Name & address of issuing organisation:

National Bureau of Standards
Bldg 225 Room B151
Gaithersburg MD, 20899
USA

Tel: 301 975 2833
Tlx: 197674 NBS UT

Structure of code:

  1. 0005 GOSNET United States Federal Government Open System Interconnection Network
  2. No check digits are needed as the whole message has a checking mechanism.

Display Requirements:

None except that all fields are left justified

Description of organizations covered by the coding system:

NBS will assign a sub value to any company or organizations that participates in the Government Open System Interconnection Network. This program encompasses governmental offices throughout the world.

Notes on use of the code:

The ICD code forms the initial part of the OSI network addressing and naming tree as depicted in Addendum 2 to ISO 8348.

Sponsoring authority:

American National Standards Institue : ANSI

Date of issue of ICD:

February 1988

Additional comments:

None

 

 

 

0006

Registration Information

ICD:

0006

Name of coding system:

USA DOD OSI NETWORK

Name & address of issuing organisation:

Defense Communication Agency
DSEC - R130
1860 Wiehle Ave
Reston VA, 22090-5500

Tel: 703 437-2802
Fax: 703 437-2382

Structure of code:

  1. 0006 DODNET Open System Interconnection Network for the Department of Defense USA.
  2. No check digits are needed as the whole message has a checking mechanism.

Display Requirements:

None except that all fields are left justified.

Description of organizations covered by the coding system:

US DOD will assign a sub value to any commands, the bases, or field activities that participates in the DOD OSI network program. The program encompasses all military commands throughout the entire world.

Notes on use of the code:

The ICD code forms the initial part of the OSI network addressing and naming tree as depicted in Addendum 2 to ISO 8348.

Sponsoring authority:

American National Standards Institue : ANSI

Date of issue of ICD:

February 1988

Additional comments:

None

 

 

0007

Registration Information

ICD:

0007

Name of coding system:

Organisationsnummer

Name & address of issuing organisation:

The National Tax Board
(Riksskatteverket, RSV)
171 94 SOLNA
SWEDEN

Tel: 08 981520

Structure of code:

1) 10 digits.
1st digit = Group number
2nd - 9th digit = Ordinalnumber1st digit
= Group number
10th digit = Check digit

2) Last digit.

Display Requirements:

Single group of 10 digits.

Description of organizations covered by the coding system:

All persons registered in Sweden for tax purposes.

Notes on use of the code:

The third digit in the organisation number is never lower than 2 in order to avoid it being confused with personal numbers.

Sponsoring authority:

Organization for Data Exchange by Tele Transmission in Europe : ODETTE

Date of issue of ICD:

November 1986

Additional comments:

None

 

 

 

0008

Registration Information

ICD:

0008

Name of coding system:

LE NUMERO NATIONAL

Name & address of issuing organisation:

Ministere De L'interieur et de la Fonction Publique
Cite administrative de l'Etat,
Tour des Finances
Bd. Pacheco. 19 - Bte 20
1010 Bruxelles.

Structure of code:

  1. 13 characters
  2. 8th & 9th characters

Display Requirements:

Four groups
Group 1 = single digit
Group 2 = six digits
Group 3 = two digits (check digits)
Group 4 = four digits

Description of organizations covered by the coding system:

Business registered for tax purposes.

Notes on use of the code:

None

Sponsoring authority:

Organization for Data Exchange by Tele Transmission in Europe : ODETTE

Date of issue of ICD:

April 1986

Additional comments:

None

 

 

 

0009

Registration Information

ICD:

0009

Name of coding system:

SIRET-CODE

Name & address of issuing organisation:

DU PONT DE NEMOURS (FRANCE) S.A.
137, rue de l'Universite
F-75334, PARIS Cedex 07

Tel: 1 45 50 65 50

Structure of code:

  1. 14 digits
  2. None

Display Requirements:

In four groups
Groups 1 - 3 = three digits each
Group 4 = five digits

Description of organizations covered by the coding system:

Used for CEFIC Trials.

Notes on use of the code:

None

Sponsoring authority:

 

Date of issue of ICD:

April 1988

Additional comments:

None

 

 

 

0010

Registration Information

ICD:

0010

Name of coding system:

Organizational Identifiers for Structured Names under ISO 9541 Part 2

Name & address of issuing organisation:

Association for Font Information Interchange : AFII
2961 Copa de Oro,
Los Alamites
California 90720
USA

Tel: 1 213 333 4642
Fax: 1 213 333 4664

Structure of code:

  1. Between 1 - 14 characters (letters, digits and hyphens only).
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Any organization which applied to be covered under visions of ISO 9541-2, in order that they may create structured names as defined in the above standard.

Notes on use of the code:

The organizational codes established under this coding systems constitute the registered organizational identifiers recognised under ISO 9541-2. That standard effectively establishes agreements under which, as allowed by clauses 5.1 and 5.3 of ISO 6523, both the ICD and the organization name are generally omitted from the SIO, and thus only the organization code portion of the SIO is interchanged.

Sponsoring authority:

Association for Font Information Interchange : AFII

Date of issue of ICD:

April 1988

Additional comments:

None

 

 

 

0011

Registration Information

ICD:

0011

Name of coding system:

International Code Designator for the Identification of OSI-based, Amateur Radio Organizations, Network Objects and Application Services.

Name & address of issuing organisation:

The Radio Amateur Telecommunications Society
206 North Vivyen Street
Bergenfield, New Jersey 07621

Tel: 201-387-8896

Structure of code:

  1. The format of the code is: Class Instance
    a. The Class is a field which indicates the general
    category of object such as the identified
    organization, network element or application
    services.
    b. The Instance is a field which indicates the specific
    instance of the organization, network element
    or application service.
    c. These fields shall be separated by any non-alphabetic,
    non-numeric, printable IA5 character.
  2. None

Display Requirements:

The "Class" and "Instance" field combine to unique identify a particular organization, network element or application service. In applications where the "Instance" implicity reflects the "Class" to the user, the "Class" field may be omitted.

Description of organizations covered by the coding system:

Amateur Radio groups which wish to participate in the OSI-based network fostered by our work and the work of our members and affiliated groups.

Notes on use of the code:

Specific object and attribute naming conventions are currently being defined.

Sponsoring authority:

American National Standards Institute : ANSI

Date of issue of ICD:

April 1988

Additional comments:

None

 

 

 

0012

Registration Information

ICD:

0012

Name of coding system:

European Computer Manufacturers Association : ECMA

Name & address of issuing organisation:

European Computer Manufacturers Association
rue du Rhone 114
1204 Geneva
SWITZERLAND

Tel: 41 22 735 36 34
Tlx 22288 ECMA CH

Structure of code:

  1. Three fields
    First field = ICD
    Second field = Organization Code, four-digit number1000-9989
    Third field = Organization Name, upto 250 characters
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Member companies of ECMA

Notes on use of the code:

None

Sponsoring authority:

European Computer Manufacturers Association : ECMA

Date of issue of ICD:

September 1988

Additional comments:

None

 

 

 

0013

Registration Information

ICD:

0013

Name of coding system:

VSA FTP CODE (FTP = File Transfer Protocol)

Name & address of issuing organisation:

Verband der Automobilindustrie e.V.,
Westendstrasse 61,
6000 Frankfurt/M.1,
GERMANY

Tel: 0 69 75 702 81
Tlx: 411293

Structure of code:

  1. Four fields
    First field = four digit, ICD code
    Second field = six characters
    Third field = eight characters, identification of
    organization.
    Fourth field = six characters, special identification
    (e.g sub-address) if required.
  2. None

Display Requirements:

Identification of the organization field may only use capital letters, digits 1 -9 and hyphens.

Description of organizations covered by the coding system:

Motorcar manufacturer and motor suppliers

Notes on use of the code:

The code serves the addressing between the communicating partners

Sponsoring authority:

Deutsches Institut fur Normung e.V. : DIN

Date of issue of ICD:

April 1989

Additional comments:

None

 

 

 

0014

Registration Information

ICD:

0014

Name of coding system:

NIST/OSI Implememts' Workshop

Name & address of issuing organisation:

NIST/OSI Implememts' Workshop

 

United States Department of Commerce
National Institute of Standards and Technology
Gaithersburg, Maryland 20899
USA

Tel: 301 975 2833
Tlx: 197674

Structure of code:

  1. 0014 OWI NIST Workshop for Implementors of OSI
  2. No check digits are needed as the whole message has checking mechanism

Display Requirements:

None, except that all fields are left justified.

Description of organizations covered by the coding system:

NIST/OSI Workshop attenders will assign a sub value to any special interest group that is approved and chartered by the Workshop, if it is appropriate to assign such sub values. The Workshop is an open, public, international forum.

Notes on use of the code:

The ICD code forms the initial part of the Workshop naming and addressing tree.

Sponsoring authority:

United States Department of Commerce.

Date of issue of ICD:

August 1989

Additional comments:

None

 

 

 

0015

Registration Information

ICD:

0015 (PROVISIONAL)

Name of coding system:

Electronic Data Interchange : EDI

Name & address of issuing organisation:

Avon Rubber p.l.c.
Bath Road
Melksham
Wiltshire
SN12 8AA

Tel: 0225 703101
Fax: 0225 707880

Structure of code:

  1. details not received yet

2)

Display Requirements:

Details not received yet

Description of organizations covered by the coding system:

Details not received yet

Notes on use of the code:

None

Sponsoring authority:

 

Date of issue of ICD:

Not confirmed, awaiting above details

Additional comments:

None

 

 

 

0016

Registration Information

ICD:

0016

Name of coding system:

EWOS Object Identifiers

Name & address of issuing organisation:

EWOS (European Workshop for Open Systems)
Rue de Stassart 36,
B-1050 Brussels,
BELGIUM

Tel: 32 2 511 7455
Fax: 32 2 511 8723

Structure of code:

  1. Digit ICD code = 0016
    Organization Code = 4 characters
    Organization Name = 34 characters
  2. None

Display Requirements:

Communication : A solidus (/) is used as a separate, the SIO shall be terminated by a double solidus(//).
Display : When the SIO is displayed or printed, the ICD, the organization code and the organization name shall be separated by one or more spaces.

Description of organizations covered by the coding system:

EWOS is the European Regional Workshop for the elaboration of Functional standards, the taxonomy for which is described in JTC 1 TR 10000, in cooperation with the other Regional Workshops N-IOW and AOW) in order to ensure International harmonization.

Notes on use of the code:

  1. In the SIO the Organization Name will normally be omitted
  2. The code is primarily intended for the registration of Objects Identifiers according to ISO 8824:
    Level 1: iso (1)
    Level 2: identified-organization (3)
    Level 3: ewos (0016)
    Level 4: and higher: (defined by EWOS conventions)

Sponsoring authority:

European Workshop for Open Systems

Date of issue of ICD:

October 1990

Additional comments:

None

 

 

 

0017

Registration Information

ICD:

0017

Name of coding system:

COMMON LANGUAGE

Name & address of issuing organisation:

Data Communications Technology Planning
Telcordia
Room 1F-359
331 Newman Springs Road
P O Box 7020, Red Bank
NJ 07701-7020
USA

Tel: 1 201 758 2198
Fax: 1 201 530 6875

Structure of code:

  1. Two fields
    a. Place Code = four characters,derived from location name.
    b. State/Province/Country code = two characters, derived from the location name
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Telecommunication administrations and public carriers.

Notes on use of the code:

Codes for named populated places, geographic places, geopolitical places, outlaying areas, and other related entities of the state of the United States, provinces and territories of Canada, countries of the world, and other unique areas. Also for the identification of organizations, places, equipment and governmental entities by the telecommunication industry.

Sponsoring authority:

American National Standards Institute : ANSI

Date of issue of ICD:

March 1990/ Amended April 2000

Additional comments:

None

 

 

 

0018

Registration Information

ICD:

0018

Name of coding system:

SNA/OSI Network

Name & address of issuing organisation:

International Business Machines Corporation : IBM
IBM Bldg. 678
1001 Winstead Drive
Cary, NC 27513
USA

Tel: 1 919 301 4004

Structure of code:

  1. xxx SNA-OSI NET Open Systems Interconnection Network
  2. None, as the whole message has a checking mechanism.

Display Requirements:

None, except that all fields are left justified.

Description of organizations covered by the coding system:

Any company or organization that participates in an SNA/OSI networking environment. This program encompasses companies throughout the world.

Notes on use of the code:

The ICD code will also form the initial part of the OSI Network addressing and naming tree as depicted in Addendum 2 to ISO 8348.

Sponsoring authority:

International Business Machines Corporation : IBM

Date of issue of ICD:

May 1990

Additional comments:

None

 

 

 

0019

Registration Information

ICD:

0019

Name of coding system:

Air Transport Industry Services Communications Network

Name & address of issuing organisation:

International Air Transport Association
IATA Centre
Route de l'Aeroport 33
P.O.Box 672

CH-1215 Geneva 15 Airport
Switzerland

Structure of code:

  1. ICD IATA International Air Transport Association
  2. No check digits are needed as the whole message has a checking mechanism.

Display Requirements:

None at the present time except that all fields are left justified.

Description of organizations covered by the coding system:

IATA will assign a sub value to any company or organisations that participates in aeronautical telecommunications networks. This program encompasses companies and organizations worldwide.

Notes on use of the code:

The ICD code forms the initial part of the OSI network addressing and naming tree as depicted in Addendum 2 to ISO 8348.

Sponsoring authority:

 

Date of issue of ICD:

Provisional

Additional comments:

This ICD is allocated on a provisional basis, awaiting confirmation from IATA.

 

 

 

0020

Registration Information

ICD:

0020

Name of coding system:

European Laboratory for Particle Physics: CERN

Name & address of issuing organisation:

European Laboratory for Particle Physics
CERN
1211 Geneva 23
Switzerland.

Tel: 41 22 767 6111
Fax: 41 22 767 7155

Structure of code:

  1. 4 Digit ICD code.
    Organization code upto 14 characters.
    Organization name upto 250 characters.
  2.  

  3. No check digits needed.

Display Requirements:

None

Description of organizations covered by the coding system:

CERN itself and academic institutes collaborating with CEN.

Notes on use of the code:

The ICD code forms the initial part of the OSI network addressing and naming tree as depicted in Addendum 2 of ISO8348.

Sponsoring authority:

European Laboratory for Particle Physics: CERN.

Date of issue of ICD:

August 1990

Additional comments:

None

 

 

 

0021

Registration Information

ICD:

0021

Name of coding system:

SOCIETY FOR WORLDWIDE INTERBANK FINANCIAL TELECOMMUNICATION S.W.I.F.T.

Name & address of issuing organisation:

SOCIETY FOR WORLDWIDE INTERBANK FINANCIAL

TELECOMMUNICATION S.W.I.F.T.
Avenue Adele,1
B - 1310 La Hulpe
BELGIUM

Tel: +32 2 6553111
Fax: +32 2 6553226

Structure of code:

  1. ICD 4 Digits
    Organization code upto 11 characters
    Organization name upto 250 characters
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Bank's identifiers for financial transfer on the S.W.I.F.T. Network.

Notes on use of the code:

To be used for assignment of object identifiers (ISO 8824/8825)

Sponsoring authority:

S.W.I.F.T.

Date of issue of ICD:

September 1990

Additional comments:

None

 

 

 

0022

Registration Information

ICD:

0022

Name of coding system:

OSF Distributed Computing Object Identification

Name & address of issuing organisation:

Open Software Foundation
11 Cambridge Center
Cambridge, MA 02142
USA

Tel : 617 621 8700
Fax : 617 621 0631

Structure of code:

  1. Organization code : full 4- character code without spaces or hyphens.
    Organization name : at most 250 characters and shall consist of the legal name or alternative names.
  2. None.

Display Requirements:

Display of SIO should be in the order of ICD, organization code and organization name where the components are separated by spaces.

Example: for the organization "OSF"

SIO representation ICD CODE NAME

communication: xxxx/xxxx/OSF//
display: xxxx xxxx OSF

Description of organizations covered by the coding system:

Member organizations of Open Software Foundation - currently OSF has 205 members located in 37 countries in the North America,South America, Europe, Asia, Africa and Australia.

Notes on use of the code:

OSF provides public domain software in OS, ISO networking and management. The initial use of the coding system are for identifying the following objects in OSF's distributed computing environment:
: the attributes of entries in the distributed directory,
: the object class of each entry in the directory,
: the type of name components (RDNs),
: the communication protocol profiles,
: the interfaces offered by distributed services.

Sponsoring authority:

American National Standards Institute : ANSI

Date of issue of ICD:

September 1990

Additional comments:

None

 

 

 

 

0023

Registration Information

ICD:

0023

Name of coding system:

Nordic University and Research Network: NORDUnet

Name & address of issuing organisation:

NORDUnet
c/o SICS
P O Box 1263
S-16428 KISTA
Sweden

Tel. +46 8 7521563
Fax. +46 8 7517230

Structure of code:

  1. ICD Code - 4 digits
    Organisation code - upto 14 characters
    Organisation Name - upto 250 characters
  2. No check digits needed.

Display Requirements:

None

Description of organizations covered by the coding system:

The coding system covers the following national research networking organizations in the five Nordic countries:
- Finnish University and Research Network (FUNET)
- SURIS (Island)
- Swedish University Network (SUNET)
- UNI.C (Denmark)
- UNINETT (Norway)
They together comprise the NORDUnet network currently connecting more than 15,000 hosts.

Notes on use of the code:

The ICD code forms the initial part of the OSI network addressing and tree as depicted in Addendum 2 of ISO8348.

Sponsoring authority:

NORDUnet and the above mentioned five national networking organizations.

Date of issue of ICD:

January 1991

Additional comments:

None

 

 

 

0024

Registration Information

ICD:

0024

Name of coding system:

Digital Equipment Corporation: DEC

Name & address of issuing organisation:

Digital Equipment (Europe) S.A.R.L.
B.P. 129 - Sophia Antipolis
06561 Valbonne Cedex
France

Tel: 33 92 95 51 11
Fax: 33 93 65 34 24

Structure of code:

  1. Four digit ICD code
    Organisation code upto 14 characters
    Organisation name upto 250 characters
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Digital Equipment Corporation and associated companies

Notes on use of the code:

The ICD code forms the initial part of the OSI network addressing, as described in ISO8348 Addendum 2.

Sponsoring authority:

Digital Equipment Corporation

Date of issue of ICD:

January 1991

Additional comments:

None

 

 

 

0025

Registration Information

ICD:

0025

Name of coding system:

OSI ASIA-OCEANIA WORKSHOP

Name & address of issuing organisation:

OSI ASIA-OCEANIA WORKSHOP
c/o Interoperability Technology Association for Information Processing, Japan
Sumito Gaien Bldg. 3F
24 Daikyo-cho
Shinjuku-ku
Tokyo 160
JAPAN

Tel: +81-3-3358-2721
Fax: +81-3-3358-4753

Structure of code:

  1. Number of the characters and their significance as defined in clause 3 of ISO6523
    ICD = 4 characters
    Organization code = upto 14 characters
    Organization name = upto 250 characters
  2. No identification of check digits

Display Requirements:

As defined in clause 4 of ISO6523

Description of organizations covered by the coding system:

Organizations working on the establishment of OSI functional standard in AOW, such as the AOW SIGs (Special Interest Groups)

Notes on use of the code:

The code is used as an element of object identifiers which need to be assigned relating the ISPs (International Standardized Profiles) that AOW is working on.

Sponsoring authority:

AOW (Asia Oceania Workshop)

Date of issue of ICD:

February 1991

Additional comments:

None

 

 

 

0026

Registration Information

ICD:

0026

Name of coding system:

NATO ISO6523 ICDE coding scheme

Name & address of issuing organisation:

North Atlantic Treaty Organisation (NATO)
NATO HQ
Bvd Leopold III
B - 1110 Brussels
Belgium

attention: Mr S Seiffert
DS/ICP Section
(TSGCEE SG/9 Secretary)

Tel: 010 32 2 728 4632
Fax: 010 32 2 728 4103

Structure of code:

  1. ICD Code - 4 digits
    Organisation code up to 14 characters
    Organisation name up to 250 characters
  2. No check digits

Display Requirements:

None

Description of organizations covered by the coding system:

NATO OSI networks

Notes on use of the code:

The ICD code forms the initial part of the OSI network addressing and naming tree depicted in Addendum 2 of ISO8348

Sponsoring authority:

British Standards Institution : BSI

Date of issue of ICD:

March 1991

Additional comments:

None

 

 

 

0027

Registration Information

ICD:

0027

Name of coding system:

Aeronautical Telecommunications Network (ATN)

Name & address of issuing organisation:

International Civil Aviation Organization (ICAO)
Communications Section, Air Navigation Bureau
1000 Sherbrooke Street West
Montreal, Quebec H3A 2R2
CANADA

Structure of code:

  1. /XXXX/ICAO/International Civil Aviation Organization
  2. No check digits

Display Requirements:

None

Description of organizations covered by the coding system:

ICAO will assign a sub-value to its Contracting States

Notes on use of the code:

The ICD code forms the initial part of the ISO network addressing and naming tree as depicted in Addendum No 2 to ISO 8348

Sponsoring authority:

British Standards Institution : BSI

Date of issue of ICD:

June 1991

Additional comments:

None

 

 

 

0028

Registration Information

ICD:

0028

Name of coding system:

International Standard ISO 6523

Name & address of issuing organisation:

Styria Federn GmbH
Postfach 101
A-8750 Judenburg
AUSTRIA

Structure of code:

  1. 14 characters identifying STYRIA FEDERN GmbH
  2. no check digits

Display Requirements:

No separators

Description of organizations covered by the coding system:

ODETTE - Organisation for Data Exchange through Tele Transmission in Europe

Notes on use of the code:

None

Sponsoring authority:

Osterreichisches Normungsinstitut (ON)

Date of issue of ICD:

June 1991

Additional comments:

None

 

 

 

0029

Registration Information

ICD:

0029

Name of coding system:

The All-Union Classifier of Enterprises and Organisations

Name & address of issuing organisation:

General Computing Centre of the State
Committee of the USSR on Statistics
44 Izmailovskoye Chosse
Moscow 105679
U S S R

Structure of code:

  1. 8 character in digits
    The first 7 digits indicate the ordinal numberof an organization
  2. From 0 to 9 including one check digit

Display Requirements:

The check digit is given without a space

Description of organizations covered by the coding system:

All organisations of the USSR

Notes on use of the code:

None

Sponsoring authority:

The State Committee of the USSR for Standardization & Metrology (GOMST)

Date of issue of ICD:

August 1991

Additional comments:

None

 

 

 

0030

Registration Information

ICD:

0030

Name of coding system:

AT&T/OSI Network

Name & address of issuing organisation:

AT&T
Standards and Regulatory Support
Room 5A256
Route 202-206N
Bedminster
NJ 07921
UNITED STATES OF AMERICA

Structure of code:

  1. ICD
  2. Organization Code, 1-14 characters
  3. Organization Name, upto 250 characters

Display Requirements:

None except that all fields are left justified

Description of organizations covered by the coding system:

Any organizations in an AT&T/OSI networking environment. This program encompasses organizations throughout the world.

Notes on use of the code:

The ICD code will also form the Initial Domain Part of the OSI network addressing and naming tree as specified in Addendum 2 to ISO 8348.

Sponsoring authority:

American National Standards Institute (ANSI) - USA

Date of issue of ICD:

September 1991

Additional comments:

None

 

 

 

0031

Registration Information

ICD:

0031

Name of coding system:

EDI Partner Identification Code

Name & address of issuing organisation:

Odette NL
Europaplein 2
1078 GZ AMSTERDAM

Tel: 020 – 5491212
Fax: 020 – 6463857

Structure of code:

  1. ICD Code .... N4
    District Number of Chamber of Commerce .... N2
    Company number according to Chamber of
    Commerce .... N12
    Sub-address .... AN 6 (if required)

Display Requirements:

N.A.

Description of organizations covered by the coding system:

Partners in assembly industry

Notes on use of the code:

To identify EDI partners

Sponsoring authority:

NNI - Delft - The Netherlands

Date of issue of ICD:

October 1991

Additional comments:

None

 

 

 

0032

Registration Information

ICD:

0032

Name of coding system:

Telecom Australia

Name & address of issuing organisation:

Australia Telecommunications Corporation
Forward Network Planning Unit
11/172 Williams Street
Melbourne
AUSTRALIA 3000

Tel: 613 634 7878
Fax: 613 670 2562

Structure of code:

  1. Delimiter between ICD and Organisation code to be 3 spaces
  2. Delimiter between Organisation name and Organisation code to be 2 spaces
  3. Delimiter between names within the Organisation name to be 2 spaces
  4. No check digits

Display Requirements:

As defined in clause 4 of ISO 6523

Description of organizations covered by the coding system:

This would be Telecom Australia and its associated Companies both nationally and internationally

Notes on use of the code:

The code is used as an element of Object Identifier when defining objects within Telecom Australia. In addition the code shall be used as an element of NSAP addressing.

Sponsoring authority:

Telecom Australia

Date of issue of ICD:

October 1991

Additional comments:

None

 

 

 

0033

Registration Information

ICD:

0033

Name of coding system:

S G W OSI Internetwork

Name & address of issuing organisation:

S G Warburg Group Management Ltd
1 Finsbury Avenue
LONDON
EC2M 2PA

Tel: 071 606 1066
Fax: 071 382 4800

Structure of code:

  1. S G W OSI
  2. S G Warburg Group Management Ltd

Display Requirements:

None

Description of organizations covered by the coding system:

Exclusive use by S G Warburg locations worldwide

Notes on use of the code:

Exclusive use by S G W

Sponsoring authority:

BSI UK

Date of issue of ICD:

November 1991

Additional comments:

Contact for enquiries at S G W: Tim Ecott, Extn 3840

 

 

 

0034

Registration Information

ICD:

0034

Name of coding system:

Reuter Open Address Standard

Name & address of issuing organisation:

Reuters Ltd
85 Fleet Street
LONDON
EC4P 4AJ

Tel: 071 250 1122
Tlx: 23222

Structure of code:

  1. According to ISO 8348 Addendum 2
  2. There are no check digits

Display Requirements:

None

Description of organizations covered by the coding system:

Reuters and associated companies, their customers and suppliers.

Notes on use of the code:

To be used in the formation of OSI Network Service Access Point (NSAP) addresses

Sponsoring authority:

BSI IST/6 Technical Committee

Date of issue of ICD:

November 1991

Additional comments:

None

 

 

 

0035

Registration Information

ICD:

0035

Name of coding system:

ISO 6523 - ICD

Name & address of issuing organisation:

The British Petroleum Co Plc
Britannic House
1 Finsbury Circus
LONDON
EC2M 7BU

Tel: 071 496 4054
Fax: 071 496 4540
Tlx: 888811

Structure of code:

1)

2)

Display Requirements:

None

Description of organizations covered by the coding system:

British Petroleum Ltd businesses including (but not limited to) BP Exploration International, BP Oil International, BP Chemicals, BP Research, BP Finance, BP Engineering.

Notes on use of the code:

This code will be used internationally by BP thus a non-geographic code is requested.

Sponsoring authority:

British Standards Institute/ISO 6523-ICD

Date of issue of ICD:

November 1991

Additional comments:

This will be the AFI:IDI for the BP Group OSI Network implementation worldwide

 

 

 

0036

Registration Information

ICD:

0036

Name of coding system:

TeleTrust Object Identifiers

Name & address of issuing organisation:

TeleTrust Deutschland e.V.
c/o GMD
Dolivostrasse 15
D-6100 Darmstadt
GERMANY

Tel: 49 6151 869 700
Fax: 49 6151 869 785

Structure of code:

  1. Organization code: TeleTrust
  2. Organization name: TeleTrust-Deutschland-e.V.

Display Requirements:

As per ISO 6523 Clause 4

Description of organizations covered by the coding system:

TeleTrust Deutschland is a group of 16 companies (vendors, software houses, user and research organizations) organized to promote trust worthiness in Open Systems, ie in particular to contribute to the development, the acceptability and the legal basis of Digital Signatures for the purpose of communication and co-operation of Open Systems.

Notes on use of the code:

a) In the SIO the Organization name will normally be omitted.

b) The code is primarily intended for the registration of Object Identifiers for security related objects according to ISO/IEC 8824
Level 1: iso(1)
Level 2: identified-organization(3)
Level 3: teletrust(0036)
Level 4 and higher: (defined by TeleTrust conventions)

Sponsoring authority:

BSI

Date of issue of ICD:

November 1991

Additional comments:

None

 

 

 

0037

Registration Information

ICD:

0037

Name of coding system:

LY-tunnus

Name & address of issuing organisation:

National Board of Taxes
(Verohallitus)
Haapanimenk 7-9B
SF-00530 Helsinki
FINLAND

Tel: 010 3580 39621
Fax: 010 3580 39624247

Structure of code:

1) 8 digits
1st-7th digit = number
8th digit = check number

2) digit

Display Requirements:

Single group of 8 digits

Description of organizations covered by the coding system:

All organizations in Finland included juridical persons and associations

Notes on use of the code:

It is possible to add 0-4 characters set to the code for more detailed use of one organization. Characters are digits or capital letter.

Sponsoring authority:

Standardization body of Finland (SFS)

Date of issue of ICD:

February 1992

Additional comments:

None

 

 

 

0038

Registration Information

ICD:

0038

Name of coding system:

The Australian GOSIP Network

Name & address of issuing organisation:

Standards Australia
80 Arthur Street
P O Box 458
North Sydney
NSW 2059
AUSTRALIA

Tel: 010 612 963 4111
Fax: 010 612 959 3896

Structure of code:

  1. NSAP address: maximum length: 20 codes including the ICD code
  2. No check digit

Display Requirements:

None

Description of organizations covered by the coding system:

Australian government departments and agencies at federal, state and local levels as well as other GOSIP conferment groups. GOSIP groups from nearby countries have been invited to use this scheme too.

Notes on use of the code:

As noted above it will be used as the initial identifier of an NSAP coding scheme.

Sponsoring authority:

Standards Australia (who will hold the registration in trust for the Australian GOSIP registration scheme)

Date of issue of ICD:

March 1992

Additional comments:

None

 

 

 

0039

Registration Information

ICD:

0039

Name of coding system:

The OZ DOD OSI Network

Name & address of issuing organisation:

The Australian Department of Defence
Communications and Information Branch
Russell Offices (B-3-25)
P O Box E33
Queen Victoria Terrace
Canberra
ACT 2600
AUSTRALIA

Tel: 010 616 265 3730
Fax: 010 616 265 3601

Structure of code:

  1. 0039/OZDOD DEFNET/Australian Department of Defence OSI Network
  2. No check digits needed as the whole message has a checking mechanism

Display Requirements:

None except all fields are left justified

Description of organizations covered by the coding system:

The Australian DOD is the Australian Government military organisation which looks after the defence requirements of the country.

Notes on use of the code:

The ICD code forms the initial part of the OSI naming and addressing tree as depicted in ISO 8348/Add 2 standard. Format of the tree is described in the Australian GOSIP Manuals and used globally.

Sponsoring authority:

Standards Australia

Date of issue of ICD:

March 1992

Additional comments:

None

 

 

 

0040

Registration Information

ICD:

0040

Name of coding system:

Unilever Group Companies

Name & address of issuing organisation:

Information Technology Group
Unilever Plc
Unilevr House
P O Box 68
LONDON
EC4P 4BQ

Tel: 071 822 6763
Fax: 071 822 5996

Structure of code:

  1. 4 digits 0-9
  2. No check digits

Display Requirements:

None

Description of organizations covered by the coding system:

Group companies of Unilever Plc and/or Unilever NV.

Notes on use of the code:

To be used in data communications to form part of the Network Address as defined in ISO 8348. The ISO 6523 ICD IDI format with Binary syntax will be used.

Sponsoring authority:

BSI

Date of issue of ICD:

March 1992

Additional comments:

None

 

 

 

0041

Registration Information

ICD:

0041

Name of coding system:

Citicorp Global Information Network

Name & address of issuing organisation:

Citicorp Global Information Network
One Court Square
48th floor
Long Island City, NY 11120
USA

Tel: 1 718 248 2990
Fax: 1 718 248 2767

Structure of code:

  1. ICD CGIN Citicorp Global Information Network
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Any company or organization that participates in a Citicorp Global Information network environment. This program encompasses companies throughout the world.

Notes on use of the code:

The ICD code will also form the initial part of the Citicorp Network addressing, object identifier tree and naming tree as depicted in Addendum 2 to ISO8348

Sponsoring authority:

ANSI

Date of issue of ICD:

April 1992

Additional comments:

None

 

 

 

 

0042

Registration Information

ICD:

0042

Name of coding system:

DBP Telekom Object Identifiers

Name & address of issuing organisation:

DBP Telekom
Product Development Telesec
P.O. Box 10 00 20
D - 5900 Siegen
GERMANY

Tel : +49 271 708 1600
Fax : +49 271 21 835

Structure of code:

  1. Organisation code: four numeric digits (ICD)
  2. Organisation name: Deutsche Bundespost Telekom

Display Requirements:

The display of the code is as per ISO 6523 clause 4, however, its use in restricted to the ISO register. The presentation of the organisation name in a certain application is decided individually by the requirements of the application.

Description of organizations covered by the coding system:

Telekom subdivisions and customers using Telekom applications & communication services.

Notes on use of the code:

1) The ICD is primarily intended for the registration of Object Identifiers according to ISO8824/8825 (ANS.1) to be used for the identification resp. registration of:
- application layer protocols,
- file & document formats,
- information objects,
- local/remote procedures.
The OID structure and the inclusion of the ICD therein is given below:
level 1: iso(1)
level 2: identifiedOrganisation(3)
level 3 (ICD): dbpt(0042)
level 4 to n: (defined by Telekom)

Sponsoring authority:

DIN

Date of issue of ICD:

May 1992

Additional comments:

None

 

 

 

0043

Registration Information

ICD:

0043

Name of coding system:

HydroNETT

Name & address of issuing organisation:

Norsk Hydro a.s.
Att. Nils Hoeg,
Corporate Staff Information Systems,
Drammensveien 264
Vaekero, Oslo
P. O. Box 200
N-1321 Stabekk, Norway

Tel : +47 2 73 81 00
Fax : +47 2 73 97 87
Tlx : 72948 hydro N

Structure of code:

  1. 1) ICD code : 4 digit
    Organization code : (up to 14 characters).
    Organization name : (up to 250 characters).
  2. No check digits needed.

Display Requirements:

None

Description of organizations covered by the coding system:

Norsk Hydro a.s. is a multinational company represented with different business units in more than 25 countries.

Notes on use of the code:

The ICD code forms the initial part of the OSI network addressing as depicted in ISO 8348/AD2.

Sponsoring authority:

Norges Standardiseringsforbund. Norwegian Standards Association.)

Date of issue of ICD:

August 1992

Additional comments:

None

 

 

 

0044

Registration Information

ICD:

0044

Name of coding system:

Thai Industrial Standards Institute (TISI)

Name & address of issuing organisation:

Thai Industrial Standards Institute (TISI)
Rama VI Street
Bangkok 10400
THAILAND

TEL: +66 2 245 78 02
FAX: +66 2 247 87 41

Structure of code:

  1. Four Fields
    First field = four digits, ICD code
    Second field = three characters to represent organization group
    Third field = between 1-11 characters
    Fourth field = Organization Name, up to 250 characters
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Government: organizations, business entities, financial institutions, ect. as specified by the second field to ensure smooth inter-communication among these organizations in Thailand.

Notes on use of the code:

The ICD code forms the initial part of international addressing for Thailand.

Sponsoring authority:

Thai Industrial Standards Institute (TISI)

Date of issue of ICD:

August 1992

Additional comments:

None

 

 

 

0045

Registration Information

ICD:

0045

Name of coding system:

ICI Company Identification System

Name & address of issuing organisation:

ICI PLC
Millbank
London
SW1P 3JF

Tel: 071 834 4444
Fax: 071 834 2042

Structure of code:

  1. 1) ICD org
    Code

    1 4 5 8 9 n
    xxxx/xxxx/organisation name//
  2. None

Display Requirements:

Upper and lower case only

Description of organizations covered by the coding system:

The coding system covers all ICI Companies Worldwide.

Notes on use of the code:

The ICD code will be used to manage NSAP allocation for all ICI companies on a worldwide basis.

The organisation code is used Worldwide by ICI application systems to identify ICI registered companies in machine to machine communications.

Sponsoring authority:

BSI Standards

Date of issue of ICD:

September 1992

Additional comments:

None

 

 

 

0046

Registration Information

ICD:

0046

Name of coding system:

FUNLOC

Name & address of issuing organisation:

Philips Electronics N.V.
Corporate Standardization Department, building VH-11
Groenewoudseweg 1
P O Box 218
5600 MD Eindhoven
The Netherlands

Tel: +31 40 736985
Fax: +31 40 734269

Structure of code:

  1. 6 Decimal digits,the first 3 denoting the country in a proprietary coding system.
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Function locations identified by legal name and address; both for Philips and external parties.

Notes on use of the code:

Current applications are Philips accounting and logistic systems; new application is the identification of objects in the open network environment according to ISO8824, which starts with a party identification

Sponsoring authority:

NNI

Date of issue of ICD:

September 1992

Additional comments:

None

 

 

 

0047

Registration Information

ICD:

0047

Name of coding system:

BULL ODI/DSA/UNIX Network

Name & address of issuing organisation:

BULL S.A.
DTBG,20 Rue Dleumegaie
FRANCE 93406 Saint-Ouen

Tel: +33 (1) 49 45 51 40
Fax: +33 (1) 49 45 53 36

Structure of code:

  1. Four numeric digits
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

All structures and customers in the world using Bull Networks applications and communications services.

Notes on use of the code:

To be used in data communications to form part of the network address. The ISO6523 ICD IDI format with binary syntax will be used.

Sponsoring authority:

AFNOR

Date of issue of ICD:

September 1992

Additional comments:

None

 

 

0048

Registration Information

ICD:

0048

Name of coding system:

OSINZ

Name & address of issuing organisation:

(Open Systems Interconnection of New Zealand Inc.)
c/- P O Box 5356
Wellesley Street
Auckland
New Zealand

Tel:
Fax:

Structure of code:

  1. 8 Digits (1-4 organisation)
    (5-8 Subnet ID)
  2. None

Display Requirements:

None except all fields are left justified

Description of organizations covered by the coding system:

Organisations in New Zealand participating in OSI interop activities

Notes on use of the code:

ISO6523 ICD IDI format with binary syntax will be used

Sponsoring authority:

SANZ

Date of issue of ICD:

OCTOBER 1992

Additional comments:

None

 

 

 

0049

Registration Information

ICD:

0049

Name of coding system:

Auckland Area Health

Name & address of issuing organisation:

Auckland Area Health Board
Information Systems
Greenlane/National Women's Hospital
Greenlane West
Auckland 3
New Zealand

Tel:
Fax:

Structure of code:

  1. 8 Digits (1-4 organisation)
    (5-8 Subnet ID)
  2. None

Display Requirements:

None except all fields are left justified

Description of organizations covered by the coding system:

Health related organizations in New Zealand

Notes on use of the code:

ISO 6523 ICD IDI format with binary syntax will be used

Sponsoring authority:

SANZ

Date of issue of ICD:

October 1992

Additional comments:

None

 

 

 

0050

Registration Information

ICD:

0050

Name of coding system:

Firmenich

Name & address of issuing organisation:

Firmenich S A
7, rue de la Bergere
CH-1217 Meyrin 2
GENEVA
Switzerland

Tel: ++41 22 780 2211
Contact: Marc Gaudar

Structure of code:

  1. XXXX/XXX XXXXXXX/FIRMENICH//
  2. XXXX/XXXXXXXXXX//

Display Requirements:

  1. XXXX XXX XXXXXXX FIRMENICH
  2. XXX XXXXXXXXXX

Description of organizations covered by the coding system:

International commercial organization with 30 large and 40 small plants, in a total of 25 different countries

Notes on use of the code:

Interconnect the plants by an OSI network, essentially over X.25 carrier

Sponsoring authority:

BAKOM Switzerland

Date of issue of ICD:

October 1992

Additional comments:

None

 

 

 

0051

Registration Information

ICD:

0051

Name of coding system:

AGFA-DIS

Name & address of issuing organisation:

AGFA N.V.
Septestraat 27
2640 Mortsel
BELGIUM

Tel: + 32 3 4442111
Fax: + 32 3 4447094

Structure of code:

  1. XXXX/AGFA-DIS/AGFA-DIS//
  2. None

Display Requirements:

XXXX AGFA-DIS AGFA-DIS

Description of organizations covered by the coding system:

All medical related organisations of AGFA

Notes on use of the code:

Medical Communication

Sponsoring authority:

IBN - BELGIUM

Date of issue of ICD:

November 1992

Additional comments:

None

 

 

 

0052

Registration Information

ICD:

0052

Name of coding system:

Society of Motion Picture and Television Engineers (SMPTE)

Name & address of issuing organisation:

Society of Motion Picture and Television Engineers (SMPTE)
595 W. Hartadae Ave.
White Plains, NY 10607
USA

Tel: +1 914 761 11 00
Fax: +1 914 761 31 15

Structure of code:

  1. Three fields
    First field = ICD
    Second field = SMPTE
    Third field = Society of Motion Picture and Television Engineers

Display Requirements:

None, except that all fields are left justified

Description of organizations covered by the coding system:

Any organization which operates within or contributes to establishing SMPTE practices. This program encompasses organizations throughout the world.

Notes on use of the code:

The ICD code will also be used to identify SMPTE constituent organizations (committees, working groups, task forces, etc./), and the objects they define. The ICD code will also form the Initial Domain Part of the OSI network addressing and naming tree as specified in Addendum 2 tot ISO 8348

Sponsoring authority:

ANSI

Date of issue of ICD:

November 1992

Additional comments:

None

 

 

 

0053

Registration Information

ICD:

0053

Name of coding system:

Migros_Network M_NETOPZ

Name & address of issuing organisation:

Migros-Genossenschafts-Bund
Administration KIM-TEKO HH17
Limmatstrasse 152
8031 ZURICH

Tel:
Fax:

Structure of code:

  1. MIGROS

    MGB
  2. None

Display Requirements:

NONE

Description of organizations covered by the coding system:

Private Network for National Industrie SWISS With Backbone Netz X25 About 400 nodes (1992)

Notes on use of the code:

NONE

Sponsoring authority:

OFCOM (SWISS)

Date of issue of ICD:

December 1992

Additional comments:

None

 

 

 

0054

Registration Information

ICD:

0054

Name of coding system:

ISO6523 - ICDPCR

Name & address of issuing organisation:

Pfizer Central Research
Ramsgate Road
Sandwich
Kent
CT13 9NJ

Tel: 0304 616223
Fax:

Structure of code:

  1. As per Addendum 2 ISO8348
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Pfizer is a world-wide organization of which Pfizer Ltd is the principal UK subsidiary. It possesses a private global network

Notes on use of the code:

This code could be used internationally by Pfizer thus a non-geographic code is required. The code forms the initial part of the OSI network addressing and naming tree depicted in Addendum 2 of ISO8348.

Sponsoring authority:

BSI

Date of issue of ICD:

December 1992

Additional comments:

This will be the AFI:IDI for the Pfizer Group OSI Network implementation worldwide.

 

 

 

0055

Registration Information

ICD:

0055

Name of coding system:

Energy Net

Name & address of issuing organisation:

ABB Asea Brown Boveri Ltd
Affolterstrasse 44,
8050 Zurich

Correspondence Address:
ABB Informatik AG
C. Falbriad, TEC1.N
Haselstrasse
CH-5401 Baden

Tel: + 41 56 75 26 77
Fax: + 41 56 75 21 21

Structure of code:

  1. AFI, ICD, country code, routing domain, Area, ID, SEL
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Worldwide Private Network for the power plant, power transmission and distribution industry segment.

Notes on use of the code:

None

Sponsoring authority:

BAKOM CH-2503 Biel- Bienne, Switzerland

Date of issue of ICD:

January 1993

Additional comments:

None

 

 

 

0056

Registration Information

ICD:

0056

Name of coding system:

Nokia Object Identifiers (NOI)

Name & address of issuing organisation:

Nokia Corporation
Research Centre
P.O.Box 156
SF-02101 Espoo
FINLAND

Tel: + 358 0 43761
Fax: + 358 0 4376227

Structure of code:

  1. ICD (fixed length 4 digits)
    Organization code (variable length up to 14 characters)
    Organization name (variable length up to 250 characters)
  2. None

Display Requirements:

When the SIO is displayed or printed, the ICD, the organization code and the organization name shall be separated by one or more spaces.

Description of organizations covered by the coding system:

Nokia Corporation with its Business Groups (Telecommunications, Mobile Phones, Cables and Machinery, Consumer Electronics and Basic Industries) and its associated companies worldwide.

Notes on use of the code:

  1. In the SIO the organization name will normally be omitted
  2. The code is primarily intended for the registration of Object Identifiers according to ISO/IEC 8824:
    Level 1: iso(1)
    Level 2: identified-organization(3)
    Level 3: nokia (xxxx)
    Level 4 and higher: defined by Nokia conventions

Sponsoring authority:

Finish Standards Association SFS

Date of issue of ICD:

February 1993

Additional comments:

None

 

 

 

0057

Registration Information

ICD:

0057

Name of coding system:

Saint Gobain

Name & address of issuing organisation:

Saint Gobain
Les Miroirs
18, avenue d'Alsace
92096 PARIS La Defense Cedex 27

Monsieur Jean Dorleans

Tel: 33 1 47 62 36 05
Fax: 33 1 47 62 50 64

Structure of code:

  1. ICD 4 digits
    (AFI 47 followed by a 4 digit ICD)
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

A group of industrial companies manufacturing engineered materials located in 35 different countries.

Notes on use of the code:

To be used for assignment of: ISO8348/Add 2) A.E.T (FTAM, X.400 Psaps, and so on) and object identification (ISO8824/8825)

Sponsoring authority:

AFNOR

Date of issue of ICD:

March 1993

Additional comments:

None

 

 

 

0058

Registration Information

ICD:

0058

Name of coding system:

Siemens Corporate Network

Name & address of issuing organisation:

Siemens AG,RI SCN,
St Martin-Str. 76,
W-8000 Muenchen 90
Germany

Tel: +49 89 4133 2565
Fax: +49 89 4133 1984

Structure of code:

  1. 1) cccc(ICD) SCN (Siemens Corporate Network)
  2. No check digits as in general the whole message has a checking mechanism.

Display Requirements:

None

Description of organizations covered by the coding system:

Any company or organization that participates in the Siemens Corporate Network. This network encompasses companies and organizations throughout the world.

Notes on use of the code:

The ICD code will form the initial part of the OSI Network addressing and naming tree as depicted in Addendum 2 to ISO8348 (Network layer addressing). These addresses will uniquely identify systems within SCN and to the outside world.

Sponsoring authority:

Deutsches Institut fur Normung e.V.(DIN)

Date of issue of ICD:

April 1993

Additional comments:

None

 

 

 

0059

Registration Information

ICD:

0059

Name of coding system:

DANZNET

Name & address of issuing organisation:

DANZAS AG
Head Office
Switzerland
4051 Basel

Attn Schutz Bertrand

Structure of code:

  1. Between 1 - 4 characters (letters, digits and hyphens only).
  2. Between 1 - 12 characters (letters, digits and hyphens only).

Display Requirements:

NONE

Description of organizations covered by the coding system:

Danzas country group organizations and Head Office

Notes on use of the code:

NONE

Sponsoring authority:

OFCOM/BAKOM

Date of issue of ICD:

May 1993

Additional comments:

NONE

 

 

 

0060

Registration Information

ICD:

0060

Name of coding system:

Data Universal Numbering System (D-U-N-S Number)

Name & address of issuing organisation:

Dun and Bradstreet Ltd
Holmers Farm Way
High Wycombe
Bucks
HP12 4UL

Structure of code:

  1. Eight identification digits and a check digit. A two digit prefix will be added in the future but it will not be used to calculate the check digit.
  2. The Organization name is not part of the D-U-N-S number.

Display Requirements:

IIIIIIIIC where all characters are the digits 0 to 9, I = an identification digit and C = the check digit. When the prefix (P) is added the display requirement will be eleven digits, PPIIIIIIIIC.

Description of organizations covered by the coding system:

It is the objective of Dun and Bradstreet to allocate a D-U-N-S number to all businesses and institutions engaged in a speficic business activity.

Notes on use of the code:

The D-U-N-S Number originated to facilitate the compilation of financial status reports on those involved in business transactions but it is now widely used for other purposes also. The number has world wide recognition as a means of identifying businesses and institutions.

Sponsoring authority:

BSI/DISC

Date of issue of ICD:

JUNE 1993

Additional comments:

A full specification of scheme has been deposited with the Registration Authority

 

 

 

0061

Registration Information

ICD:

0061

Name of coding system:

SOFFEX OSI

Name & address of issuing organisation:

SOFFEX Swiss Options and Financial Futures Exchange AG.
Neumattstrasse 7
CH-8953 Dietikon
Switzerland

Structure of code:

  1. 4 numeric digits
  2. None

Display Requirements:

None except all fields are left justified

Description of organizations covered by the coding system:

Swiss financial derivatives exchange

Notes on use of the code:

This code is to assist in uniquely identifiying data network node addresses in an international supporting network for financial applications. This supporting network may have operational interfaces to other (private) data networks.

Sponsoring authority:

BAKOM - Bundesamt fuer Kommunication (Swiss Federal Office for Communication) CH-2501 Biel-Bienne, Switzerland.

Date of issue of ICD:

June 1993

Additional comments:

None

 

 

 

0062

Registration Information

ICD:

0062

Name of coding system:

Unisource Business Networks

Name & address of issuing organisation:

Unisource Business Networks B.V.
P O Box 421
2260 AK Leidschendam
The Netherlands

Tel: +31 70 332 5779
Fax: +31 70 332 6477

Structure of code:

  1. ICD 4 digits
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

International Unisource network with its customers

Notes on use of the code:

This code is used for uniquely identifying addresses systems in the international Unisource organization and also (part of) its customers.

Sponsoring authority:

Nederlands Normalisatie Instituut
P O Box 5059
2600 GB DELFT

Date of issue of ICD:

July 1993

Additional comments:

 

 

 

 

0063

Registration Information

ICD:

0063

Name of coding system:

ascomOSINet

Name & address of issuing organisation:

Ascom AG
Belpstrasse 37
CH-3000 Bern
Switzerland

Fax: +41 55 41 63 85
Tel: +41 55 41 60 04

Structure of code:

  1. ICD 4 digits
  2. None

Display Requirements:

All fields are left justified

Description of organizations covered by the coding system:

ascom

Notes on use of the code:

 

Sponsoring authority:

BAKOM Bundesamt fur Kommunication
Zukunftstrasse 44
CH-2501 Biel-Bienne
Switzerland

Date of issue of ICD:

August 1993

Additional comments:

None

 

 

 

0064

Registration Information

ICD:

0064

Name of coding system:

UTC: Uniforme Transport Code

Name & address of issuing organisation:

Foundation UTC
P.O.Box 82118
2508 EC The Hague
The Netherlands

Tel: + 31 70 35 10 777
Fax: + 31 70 35 12 025

Structure of code:

  1. ICD Code: 4 digits
    Organization code: minimum 1, maximum 8 digits
    Sequence number : minimum 1, maximum 8 digits
  2. None

Display Requirements:

Check digit according to ISO 7064-8

Description of organizations covered by the coding system:

The shipping and transport industry

Notes on use of the code:

The code identifies an individual transport or handling unit (e.g. pallet, parcel) for reasons of tracing or tracing. The unit may have an international destination.

Sponsoring authority:

NNI - The Netherlands

Date of issue of ICD:

October 1993

Additional comments:

None

 

 

 

0065

Registration Information

ICD:

0068

Name of coding system:

SOLVAY OSI CODING

Name & address of issuing organisation:

Direction Centrale Technique (Informatique Scientifique)
SOLVAY S.A
Rue de Ransbeek 310
B-1120 Bruxelles

Structure of code:

  1. Two octets, fixed lenght. The particular values of 00-00 (all zeros) and FF-FF (allones) will be reserved, so that addresses are able to comply with ECMA-117, where the ISO 6523 organization code is mapped to ECMA-117 subnetwork. This structure also permits compliance with GOSIP (FIPS PUB 146)
  2. No check digits will be used

Display Requirements:

The code should be dispalyed as XX-XX where X is an hexadecimal number.

Description of organizations covered by the coding system:

Companies member of the Solvay Group (globally consolidated), and major organizational subdivisions of such companies, including large plants or national subsidiairies.

Notes on use of the code:

Whenever possible, ISO 8348 addresses using this code will comply with FIPS PUB 146, with an End System ID of exactly 4 octets, so that the DSP can also conform to ECMA 117 where ECMA's subnet-address maps onto FIPS's Subnet ID concatenated with the End System ID.

Sponsoring authority:

IBN-Belgium

Date of issue of ICD:

December 1993

Additional comments:

None

 

 

 

 

0066

Registration Information

ICD:

0066

Name of coding system:

Roche Corporate Network

Name & address of issuing organisation:

F. HOFFMANN - LA ROCHE AG
Grenzacherstasse 124
CH-4002 BASEL
Switzerland

Structure of code:

As per Addendum 2 ISO 8348

Display Requirements:

None

Description of organizations covered by the coding system:

Hoffmann- La Roche is an international organization with a private global network. The coding system includes all affiliates belonging to the the Roche group (currently about 125 different legal entities).

Notes on use of the code:

Will be used internationaly by Roche thus a non-geographic code is required.

Sponsoring authority:

BAKOM Switzerland

Date of issue of ICD:

January 1994

Additional comments:

None

 

 

 

0067

Registration Information

ICD:

0067

Name of coding system:

ZellwegerOSINet

Name & address of issuing organisation:

Zellweger Uster AG
Wilstrasse 11
CH-8610 USTER
Switzerland

Tel: + 41 1 943 2608
Fax: + 41 1 943 3815

Structure of code:

  1. ICD 4 digits
  2. None

Display Requirements:

All fields are left justified

Description of organizations covered by the coding system:

Zellweger

Notes on use of the code:

 

Sponsoring authority:

BAKOM - Switzerland

Date of issue of ICD:

January 1994

Additional comments:

None

 

 

 

0068

Registration Information

ICD:

0068

Name of coding system:

Intel Corporation OSI

Name & address of issuing organisation:

Intel Corporation
1900 Prairie City Road
Folsom
Ca. 95630
USA

Structure of code:

  1. 4 Numeric digits
  2. None

Display Requirements:

None except all fields are left justified

Description of organizations covered by the coding system:

Intel Corporation, operating in several countries around the world.

Notes on use of the code:

The ICD code will be used to form the Initial Domain Identifier (IDI) portion of the Initial Domain Part (IDP) as described in ISO 8348 Addendum 2 for OSI NSAP addressing.

Sponsoring authority:

ANSI - USA

Date of issue of ICD:

January 1994

Additional comments:

None

 

 

 

0069

Registration Information

ICD:

0069

Name of coding system:

SITA Object Identifier Tree

Name & address of issuing organisation:

SITA
112 Avenue Charles de Gaulle
92522 NEUILLY-SUR-SEINE CEDEX
France

Structure of code:

  1. ISO(1), identified organization(3), sita(00xx)
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Airlines Aircraft Manufacturers, etc ( i.e. users of SITA Worldwide Telecommunications and Information Services)

Notes on use of the code:

SITA intends to use its OID Tree to define its own Objects for use with its OSI-based services (e.g. MHS & OSI Management)

Sponsoring authority:

SITA (as an inernational orrganization) has a class B Liason with ISO/IEC JTC1

Date of issue of ICD:

April 1994

Additional comments:

None

 

 

 

0070

Registration Information

ICD:

0070

Name of coding system:

Daimler Benz Corporate Network

Name & address of issuing organisation:

debis Systemhaus Network Services Gmbh
Erich-Herion-Strasse 13
70736 Fellbach
GERMANY

Structure of code:

  1. cccc (ICD) DBCN (Daimler Benz Corporate Network)
  2. No check digits as in general the whole message has a checking mechanism

Display Requirements:

None

Description of organizations covered by the coding system:

Any company or organization that participates in the Daimler Benz Corporate Network. This network encompassed companies and organizations throughout the world.

Notes on use of the code:

The ICD code will form the initial part of the OSI Network addressing and naming free as depicted in Addendum 2 to ISO 8348 (Network Layer addressing). These addresses will uniquely identify systems within DBCN and to the outside world.

Sponsoring authority:

Deutsches Institut fur Normung e.V. (DIN)

Date of issue of ICD:

April 1994

Additional comments:

None

 

 

 

0071

Registration Information

ICD:

0071

Name of coding system:

LEGO /OSI NETWORK

Name & address of issuing organisation:

LEGO Systems Inc
555 Taylor Road
Enfield, Conneticut 06082
USA

Tel : (203) 749 2291
Fax : (203) 763 6681

Structure of code:

  1. Three fields:
    First field = ICD
    Second field = Organization Code
    Third field = Organization Name
  2. None

Display Requirements:

None, except that all fields are left justified

Description of organizations covered by the coding system:

The organizations to be covered by the coding system include company locations and subsidaries in the United States, 15 European cities, the Far East (Japan & Korea) and Brazil. We estimate having 5000+ nodes on the LEGOnet within 3 years.

Notes on use of the code:

The ICD code will also form the Initial Domain Part of the OSI network addressing and naming tree as specified in addendum 2 to ISO 8348.

Sponsoring authority:

American National Standards Institute (ANSI) - USA

Date of issue of ICD:

May 1994

Additional comments:

It is also necessary for 1 or more of these sites to be able to connect to non-LEGO companies

 

 

 

0072

Registration Information

ICD:

0072

Name of coding system:

NAVISTAR/OSI Network

Name & address of issuing organisation:

Navistar Information Organization
Navistar International Corp
1901 South Meyers Road
Oakbrook Terrace, Illinois 60181
USA

Tel : 708-691-5517
Fax : 708-691-5738

Structure of code:

  1. Three fields:
    First field = ICD
    Second field = NAVISTAR
    Third field = NAVISTAR International Transportation Corp
  2. None

Display Requirements:

None, except that all fields are left justified

Description of organizations covered by the coding system:

Any organization that participates in the NAVISTAR/OSI networking system including:
Navistar International Corporation
Navistar International Transportation Corp
Navistar Financial Corporation
Navistar International Export Corporation
Navistar International Corporation, Canada
Navistar International Overseas Corporation

Notes on use of the code:

The ICD code will also form the Initial Domain Part of the OSI Network addressing and naming tree as specified in Addendum 2 to ISO 8348.

Sponsoring authority:

American National Standards Institute (ANSI) - USA

Date of issue of ICD:

May 1994

Additional comments:

None

 

 

 

0073

Registration Information

ICD:

0073

Name of coding system:

ICD Formatted ATM address

Name & address of issuing organisation:

Newbridge Networks Corporation
600 March Road
P O Box 13600
Kanata , Ontario
CANADA, K2K 2E6

Structure of code:

  1. Format: /XXXX/xxxxxxx/Organization Name//
    Example: /XXXX/000000/Newbridge Network Corporation//
    The xxxxxx field is a 6-digit BCD encoded number.
  2. There are no check digits

Display Requirements:

None

Description of organizations covered by the coding system:

Private ATM Networks using Newbridge ATM terminal and switching equipment.

Notes on use of the code:

Used as an ATM address prefix by

  1. Newbridge ATM terminal equipment:
    a)when performing user - network address registration
    b)transparently initiating signalled ATM connections on
    behalf of other non-ATM (LAN) devices
    c)directly initiating signaled ATM connections
  2. Newbridge ATM switching equipment used to:
    a)perform network - user address registration
    b)perform routing of Switched Virtual Connections across a
    private ATM cell switching network

Sponsoring authority:

COSIRA
c/o CGI Information Systems and Management Consultants Inc.
275 Slater Street
19th Floor
Ottawa, Ontario
CANADA, K1P 5H9

Date of issue of ICD:

June 1994

Additional comments:

None

 

 

 

0074

Registration Information

ICD:

0074

Name of coding system:

ARINC

Name & address of issuing organisation:

ARINC Incorporated
2551 Riva Road
Annapolis, MD 21401-7465
USA

Tel : + 410 266 4000
Fax : + 410 266 4040

Structure of code:

  1. ISO (1), identified organization (3), arinc (00xx)
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Owners and Customers of ARINC'S Data Network services, Information Systems and other services. Members of the Aeronautical industry.

Notes on use of the code:

ARINC will define its own Objects for use with its OSI-based systems and services. ARINC will also define Objects for use within the Aeronautical industry.

Sponsoring authority:

American National Standards Institute (ANSI)

Date of issue of ICD:

July 1994

Additional comments:

None

 

 

 

0075

Registration Information

ICD:

0075

Name of coding system:

Alcanet/Alcatel-Alsthom Corporate Network

Name & address of issuing organisation:

Alcatel Network Services Deutschland GmbH
Motostr. 25
D - 70499 Stuttgart
GERMANY

Technical Contact : Thomas Galuschka
Tel : + 49 711 821 2367
Fax : + 49 711 821 4793

Structure of code:

  1. 1) cccc (ICD) Alcanet
  2. No check digits as in general the whole message has a checking mechanism

Display Requirements:

None

Description of organizations covered by the coding system:

Any company or organization that is part of the Alcatel-Alsthom group. The network of this group (Alcanet) encompasses companies and organizations throughout the world.

Notes on use of the code:

The ICD code forms the initial part of the OSI network addressing scheme as depicted in Addendum 2 of ISO 8384

Sponsoring authority:

Deutsches Institut fur Normung e.V. (DIN)

Date of issue of ICD:

August 1994

Additional comments:

None

 

 

 

0076

Registration Information

ICD:

0076

Name of coding system:

Sistema Italiano di Identificazione di ogetti gestito da UNINFO

Name & address of issuing organisation:

UNINFO
Ente di Normazione Federato all'UNI
C.so Galileo Ferraris 93
10128 Torino
ITALY

Tel : + 3911 501 027
Fax : + 3911 501 837

Structure of code:

  1. Six digits. Organization name:variable length up to 250 characters
  2. No check digits

Display Requirements:

Space used as separator within the coding scheme of the organization name and between the organization code and the organization name.

Description of organizations covered by the coding system:

Any Italian company or organization intending for the registration of Object Identifiers according to ISO 8824

Notes on use of the code:

To be used for assignments of object identifiers according to ISO 8824 and ISO 8825

Sponsoring authority:

UNI

Date of issue of ICD:

October 1994

Additional comments:

None

 

 

 

0077

Registration Information

ICD:

0077

Name of coding system:

Sistema Italiano di Indirizzamento di Reti OSI Gestito da UNINFO

Name & address of issuing organisation:

UNINFO
Ente di Normazione Federato all'UNI
C.so Galileo Ferraris, 93
10128 Torino
ITALY

Structure of code:

  1. To be defined

Display Requirements:

To be defined

Description of organizations covered by the coding system:

Any company or organization operating in an Italian OSI networking enviroment.

Notes on use of the code:

The ICD code forms the initial part of the OSI network Addressing and naming tree depicted in Adendeum 2 of ISO 8348.

Sponsoring authority:

UNI

Date of issue of ICD:

October 1994

Additional comments:

None

 

 

 

0078

Registration Information

ICD:

0078

Name of coding system:

Mitel terminal or switching equipment

Name & address of issuing organisation:

Mitel Corporation
350 Legget Drive, P O Box 13089
Kanata ON K2K 1X3
Canada
Attn : Mr Francois Audet

Structure of code:

  1. XXX/MITEL/Mitel Corporation//
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Networks using Mitel terminal or switching equipment

Notes on use of the code:

The ICD code will form the initial part of the naming tree for:

  1. Private Integrated Services Network manufacturer specific information as the Organization identifier forming the initial part of the OBJECT IDENTIFIER tree.
  2. OSI Application Layer such as CSTA (ECMA 179).

Sponsoring authority:

COSIRA
275 Slater St, 19th Floor
Ottawa ON K1P 5H9
Canada

Date of issue of ICD:

November 1994

Additional comments:

None

 

 

 

0079

Registration Information

ICD:

0079

Name of coding system:

ATM Forum

Name & address of issuing organisation:

The ATM Forum
303 Vintage Park Drive
Foster City, CA 94404-1138
USA

Tel: +(415)-578-6860
Fax: +(415)-525-0182

Structure of code:

  1. Format includes 2 fields
    First field = ICD
    Second field = Domains Specific Part
  2. None

Display Requirements:

None, except that all fields are left justified

Description of organizations covered by the coding system:

Any organization or company that participates in the ATM Forum UNI private addressing format. The ATM Forum encompasses organizations and companies throughout the world.

Notes on use of the code:

The ICD code will also form part of the Initial Domain Part of the OSI network addressing as specified in Addendum 2 to ISO 8348

Sponsoring authority:

ANSI
11 West 42nd Street
New York 10036
USA

Date of issue of ICD:

December 1994

Additional comments:

None

 

 

 

0080

Registration Information

ICD:

0080

Name of coding system:

UK National Health Service Scheme
(EDIRA compliant)

Name & address of issuing organisation:

National Health Service
Information Management Center
15 Frederick Road
Birmingham
B15 1SD

Contact person: Mr Brian LOVE
Tel : +44 1454 261 551
Fax: +44 1454 261 581

Structure of code:

  1. Structure of EDI identifier
    Character repertoire
    The EDI identifier consists of digits only.The identifier is fixed length and therefore no separators are required.
    Length of registered organization id
    The registered organization identifier has a fixed length of 10 digits including check digit
    Subdivisions of registered organization id
    There are no formal sub-divisions of the registered organization identifier. It is intended to allocate initially from the band <10xxxxxxxc> in case it becomes necessary to assign registration sub-authorities. Sub-authorities would then be allocated bands <11xxxxxxxc>, <12xxxxxxxc> etc. allowing a possible total of 89 sub authorities. Registered organization identifiers starting <0xxxxxxxxc> are reserved for special purposes.
  2. Check sum computation
    The check sum used will be modulo 7.

Display Requirements:

None

Description of organizations covered by the coding system:

Organization highest level
Intended scope is 'legal entities' of the UK Healthcare community i.e. GPs, GDPs, NHS Hospital Trusts, Health Authorities, Health Commissioning Agencies, Health Laboratories, NHS Executive and other NHS bodies such as Blood Transfusion etc. Organizations having a legitimate interest in the Healthcare Community e.g. health insurance companies etc. will be strongly encouraged to use alternative registration schemes but may be considered for the NHS scheme on a case by case basis.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI systems

Sponsoring authority:

Association Francaise de Normalisation (AFNOR)
Tour Europe
Cedex 7
92049 Paris La Defense
FRANCE

Date of issue of ICD:

January 1995

Additional comments:

None

 

 

 

0081

Registration Information

ICD:

0081

Name of coding system:

International NSAP

Name & address of issuing organisation:

Federal Office for Communications
Zukunfstrasse 44
POSTFACH
CH-2501 Biel
Switzerland

Tel : +41 32 285 111
Fax : +41 32 285 528

Structure of code:

  1. NSAP address (detailed document on structure can be supplied on request
  2. No check digit

Display Requirements:

None

Description of organizations covered by the coding system:

Any organization requiring an international (country-independant) NSAP numbering space

Notes on use of the code:

None

Sponsoring authority:

OFCOM/Swiss Federal Office for Communications

Date of issue of ICD:

February 1

Additional comments:

None

 

 

 

0082

Registration Information

ICD:

0082

Name of coding system:

Norwegian Telecommunications Authority's, NTA'S, EDI, identifier scheme
(EDIRA compliant)

Name & address of issuing organisation:

Norwegian Telecommunications Authority
P O Box 447 Sentrum
N-0104 Oslo
NORWAY

Contact person: Mr Knut Smaaland
Tel: + 47 22 82 48 04
Fax: + 47 22 82 48 40

Structure of code:

  1. Character repertoire; the registered identifier consists of digits only, the length is variable, no separators are needed. Length of registered organization identifier; the identifier has a minimum length of 4 digits and a maximum length of 12 digits including the check digit where applicable.
    Subdivision of registered organization identifier; the first digit designates the version number of the coding system, the next two digits designates the registration authority or one of its sub-authorities, then follows the organization designator. The registered part is preceded by the ICD value when encoded in EDIFACT messages.
  2. Check digit computation; when applicable the check digit will be computed modulo 11. The check digit will be the last digit in the registered identifier.

Display Requirements:

None

Description of organizations covered by the coding system:

Any organization or part thereof in need of unique EDI identifier.

Notes on use of the code:

For use in EDIFACT messages in accordance with current national recommendation on identification of EDI objects. (EDIRA compliant)

Sponsoring authority:

Norwegian Standards Association

Date of issue of ICD:

February 1995

Additional comments:

Previously used code 56 within the UN/ECE 0007 code list.

 

 

 

0083

Registration Information

ICD:

0083

Name of coding system:

Advanced Telecommunications Modules Limited Corporate Network

Name & address of issuing organisation:

ATM Ltd
Mount Pleasant House
Cambridge
CB3 0BL
ENGLAND

Structure of code:

  1. Format includes 2 fields :
    First field = ICD
    Second field = Domain specific part
  2. None

Display Requirements:

None - all fields are left justified

Description of organizations covered by the coding system:

ATM terminal or switching equipments using the UNI private addressing format

Notes on use of the code:

The ICD code will also form part of the Initial Domain Part of the OSI network addressing as specified in Addendum 2 to ISO 8348

Sponsoring authority:

BSI

Date of issue of ICD:

March 1995

Additional comments:

None

 

 

 

0084

Registration Information

ICD:

0084

Name of coding system:

Athens Chamber of Commerce & Industry Scheme
(EDIRA compliant)

Name & address of issuing organisation:

Athens Chamber of Commerce & Industry
Akadimias Street 7
GR 108 71 Athens
Contact person: Mrs M Hliapa
Tel : +301 362-7911
Fax : +301-362-4643

Structure of code:

Structure of EDI identifier

Character repertoire
The EDI identifier consists of digits only.
The identifier has a fixed length. No separators are required.
Structure : [123] [123456] [123456] [12]
17
< >
A B C D
A : numerical value allocated by the RA to the regional sub-authority (3 digits)
B : numerical value allocated by the sub-authority to the registered organization (mandatory part of the identifier ; 6 digits)
C : numerical value used by the registered organization (free part ; 6 digits)
D : numerical check digit calculated by the registered organization; (2 digits)
Check digit computation
The check digit is modular 97 computed on ABC as one number.

Display Requirements:

None

Description of organizations covered by the coding system:

Organization highest level

The Athens Chamber of Commerce & Industry will register at the highest level: Organizations (legal persons, partnerships, sole proprietor-ships and their branch offices) registered in the business register or organizations (legal or natural persons) not registered in the business register.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI syntaxes.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

March 1995

Additional comments:

None

 

 

 

0085

Registration Information

ICD:

0085

Name of coding system:

Swiss Chambers of Commerce (Scheme)
(EDIRA compliant)

Name & address of issuing organisation:

Zurich Chamber of Commerce on behalf of the Swiss Chambers of Commerce
Bleicherweg 5
CH-8022 Zurich
SWITZERLAND

Contact person: Dr Christian Boesch
Tel : +411 221-0742
Fax : +411-211-7615

Structure of code:

Structure of EDI identifier
Character repertoire
The EDI identifier consists of digits only.
The identifier has a fixed length. No separators are required.
Structure : [123] [123456] [123456] [12]
17
< >
A B C D
A : numerical value allocated by the RA to the regional sub-authority (3 digits)
B : numerical value allocated by the sub-authority to the registered organization (mandatory part of the identifier ; 6 digits)
C : numerical value used by the registered organization (free part ; 6 digits)
D : numerical check digit calculated by the registered organization ; (2 digits)

Check digit computation
The check digit is modular 97 computed on ABC as one number.

Display Requirements:

None

Description of organizations covered by the coding system:

Organization highest level

The Swiss Chambers of Commerce will register at their highest level : Organizations (legal persons, partnerships, sole proprietor-ships and their branch offices) registered in the business register or organizations (legal or natural persons) not registered in the business register.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI syntaxes.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

March 1995

Additional comments:

None

 

 

 

0086

Registration Information

ICD:

0086

Name of coding system:

United States Council for International Business (USCIB) Scheme
(EDIRA compliant)

Name & address of issuing organisation:

United States Council for Internationa Business (USCIB)
1212 Avenue of the Americas
USA New York, NY 10036
Contact person: Mr Peter ROBINSON
Tel : +1212 354 4851
Fax : +1212 575 0327

Structure of code:

Structure of EDI identifier
Character repertoire
The EDI identifier consists of digits only.
The identifier has a fixed length. No separators are required.
Structure : [123] [123456] [123456] [12]
17
< >
A B C D
A : numerical value allocated by the RA to the regional sub-authority (3 digits)
B : numerical value allocated by the sub-authority to the registered organization (mandatory part of the identifier ; 6 digits)
C : numerical value used by the registered organization (free part ; 6 digits)
D : numerical check digit calculated by the registered organization ; (2 digits)
Check digit computation
The check digit is modular 97 computed on ABC as one number.

Display Requirements:

None

Description of organizations covered by the coding system:

Organization highest level
The United States Council for International Business will register at their highest level: Organizations (legal persons, partnerships, sole proprietor-ships and their branch offices) registered in the business register or organizations (legal or natural persons) not registered in the business register.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI syntaxes.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

March 1995

Additional comments:

None

 

 

 

0087

Registration Information

ICD:

0087

Name of coding system:

National Federation of Chambers of Commerce & Industry of Belgium Scheme
(EDIRA compliant)

Name & address of issuing organisation:

National Federartion of Chambers of Commerce & Industry of Belgium
Avenue des Arts 1-2. B 10
BE 1040 Brussels
Contact person: Mr Michael PEEREMAN
Tel : +322-217-3671
Fax : +322-217-4634

Structure of code:

Structure of EDI identifier
Character repertoire
The EDI identifier consists of digits only.
The identifier has a fixed length. No separators are required.
Structure : [123] [123456] [123456] [12]
17
< >
A B C D
A : numerical value allocated by the RA to the regional sub-authority (3 digits)
B : numerical value allocated by the sub-authority to the registered organization (mandatory part of the identifier ; 6 digits)
C : numerical value used by the registered organization (free part ; 6 digits)
D : numerical check digit calculated by the registered organization ; (2 digits)

Check digit computation
The check digit is modular 97 computed on ABC as one number.

Display Requirements:

None

Description of organizations covered by the coding system:

Organization highest level

The National Federation of Chambers of Commerce and Industry will register at their highest level. Organizations (legal persons, partnerships, sole proprietor-ships and their branch offices) registered in the business register or organizations (legal or natural persons) not registered in the business register.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI syntaxes.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

March 1995

Additional comments:

None

 

 

 

0088

Registration Information

ICD:

0088

Name of coding system:

EAN Location Code

Name & address of issuing organisation:

EAN International
rue Royale 29
B-1000 Brussels
Belgium

Tel : +32.2.218.76.74
Fax : +32.2.218.75.85

Structure of code:

  1. 13 digits including check digits
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

The mission of EAN International and its member numbering organizations is to take a leading role in establishing a global multi-industry system of identification and communication for products and services based on internationally accepted and business led standards. The objective is to improve the efficiency of integrated logistics while contributing added value to partners involved, as well as to consumers. At the end of 1994,near to 300,000 companies from a very large variety of sectors of trade and industry participated in the EAN system, through membership to one of the 66 national or pluri-national numbering organizations.

Notes on use of the code:

The ICD code is intended to be used as agency identifier in theUN/EDIFACT service and data segments, replacing the current codevalues maintained by the UN.

Sponsoring authority:

DIN

Date of issue of ICD:

April 1995

Additional comments:

None

 

 

 

0089

Registration Information

ICD:

0089

Name of coding system:

The Association of British Chambers of Commerce Ltd. Scheme
(EDIRA compliant)

Name & address of issuing organisation:

The Association of British Chambers of Commerce Ltd.
9, Tufton Street, Westminster
LONDON, SW1P 3QB
Contact person : Mrs Elizabeth Boyd-Adams
Tel : +44 71 222 1555
Fax : +44 71 799 2202

E-mail X400 G=Elizabeth, S=Boyd-Adams, O= ABCC, A=BT, C=GB

Structure of code:

Structure of EDI identifier
Character repertoire
The EDI identifier consists of digits only.
The identifier has a fixed length. No separators are required.
Structure : [123] [123456] [123456] [12]
17
< >
A B C D
A : numerical value allocated by the RA to the regional sub-authority (3 digits)
B : numerical value allocated by the sub-authority to the registered organization (mandatory part of the identifier ; 6 digits)
C : numerical value used by the registered organization (free part ; 6 digits)
D : numerical check digit calculated by the registered organization ; (2 digits)

Check digit computation
The check digit is modular 97 computed on ABC as one number.

Display Requirements:

None

Description of organizations covered by the coding system:

Organization highest level

The Association of British Chambers or Commerce Ltd will register at their highest level. Organizations (legal persons, partnerships, sole proprietor-ships and their branch offices) registered in the business register(states's Secretary of State or equiavelent) or organizations (legal or natural persons) not registered in the business register.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI syntaxes.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

June 1995

Additional comments:

None

 

 

 

0090

Registration Information

ICD:

0090

Name of coding system:

Internet IP addressing - ISO 6523 ICD encoding

Name & address of issuing organisation:

Internet Assigned Numbers Authority
c/o Joyce K. Reynolds
USC - Information Sciences Institute
4676 Admiralty Way
Marina del Rey, California 90292-6695
USA

E-mail: iana @ isi.edu
Phone: +1 310-822-1511

Structure of code:

  1. ICD
    Organization Code, 1-14 characters
    Organization name, up to 250 characters
  2. None, as the whole message has a checking mechanism

Display Requirements:

As per ISO 6523: 1984 clause 4

Description of organizations covered by the coding system:

Any organization in the Internet environment. This program encompasses organizations with upwards of 30 million users throughout the world.

Notes on use of the code:

The ICD code will also form the Initial Domain Part of the OSI network addressing and naming tree as specified in ISO 8348, Annex A.

Sponsoring authority:

ISO/IEC JTC 1/SC 6

Date of issue of ICD:

July 1995

Additional comments:

None

 

 

 

0091

Registration Information

ICD:

0091

Name of coding system:

Cisco Sysytems / OSI Network

Name & address of issuing organisation:

Cisco Systems
170 W. Tasman Drive
San Jose
CA 95134
USA

Phone + 1 408 526 4000
Fax + 1 408 426 4100

Structure of code:

  1. Three fields
    First field = ICD
    Second field = Organization Code, 1-14 characters
    Third field = Organization Name, up to 150 characters

Display Requirements:

None, except that all fields are left justified

Description of organizations covered by the coding system:

Any organization that participates in a Cisco Systems / OSI networking environment. This program encompasses organiztions throughout the world.

Notes on use of the code:

The ICD will also form the Initial Domain Part of the OSI networking addressing and naming tree as specified in Addendum 2 to ISO 8348.

Sponsoring authority:

American National Standars Institute (ANSI) - USA

Date of issue of ICD:

November 1995

Additional comments:

None

 

 

 

0092

Registration Information

ICD:

0092

Name of coding system:

Not to be assigned (see additional comments)

Name & address of issuing organisation:

 

Structure of code:

 

Display Requirements:

 

Description of organizations covered by the coding system:

 

Notes on use of the code:

 

Sponsoring authority:

 

Date of issue of ICD:

 

Additional comments:

This was originally allocated to the Danish Chamber of Commerce but due to a conflict with the UN/ECE codes they have been reallocated ICD 0096.

 

 

 

0093

Registration Information

ICD:

0093

Name of coding system:

Revenue Canada Business Number Registration
(EDIRA compliant)

Name & address of issuing organisation:

Revenue Canada
123 Slater Street, Ottawa, ON K1A OL8
Signatory name
Roderick G. Quiney, Director-General
Contact address
25 McArthur, Tower C, 7th Floor, Ottawa
Ontario CANADA K1A OL8
Tel + 1 613 941 5007
Fax + 1 613 941 8539

Structure of code:

Character repertoire
The BN contains a 15 character number (e.g. "12345 6789 RC0001") Characters are restricted to the numeric 0-9 and the alphabetics A-z. The BN is fixed length.

Length of the registered organization id
The length is up to 15 characters. Each field if used, has a fixed length.

Subdivisions of registered organization id
The identifier is sub-divided into up to 3 fixed length fields.
The Registration Number consisting of nine numeric digits may be in inherited from its Goods and Services Tax (GST) number or may be allocated from unused BN number space.
The Program Identifier consists of two character alphabetic code. the four Program Identifiers already allocated are "RC" (corporate income tax), "RM" (import/export duties), "RP" (payroll source deductions) and "RT" (goods and service tax). Two potential Program Identifiers already reserved are "VS" (vendor/supplier of goods and services to government) and "VC" (consignee as government destination/accounting point).
The Reference Number within a particular government program consists of four numeric digits.
The use of an< organization-free part> is possible at the user’s will, but is not specified as part of the registration scheme.

Check character
The BN is a 15 character broken into a 9 digit root followed by a 6 character account identifier. The last digit of the 9 root is the check digit using MOD10.

Display Requirements:

To facilitate user consultation, the BN is displayed as three components, separated by a space.

Description of organizations covered by the coding system:

The BN is a numbering system whose purpose is to uniquely identify private and public sector entities, i.e. registrants, governmentprograms and operating entity(ies).

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI systems.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

November 1995

Additional comments:

None

 

 

 

0094

Registration Information

ICD:

0094

Name of coding system:

DEUTSCHER INDUSTRIE- UND HANDELSTAG (DIHT) Scheme
(EDIRA compliant)

Name & address of issuing organisation:

Deutscher Industrie -und Handelstag (DIHT)
Adenauerallee 148
D - 53113 Bonn

Contact person: Ute Quink-Ermst
Tel : + 49 228 104 102
Fax : + 49 228 104 158

Structure of code:

Structure of EDI identifier
Character repertoire
The EDI identifier consists of digits only.
The identifier has a fixed length. No separators are required.
Structure : [123] [123456] [123456] [12]
17
< >
A B C D
A : numerical value allocated by the RA to the regional sub-authority (3 digits)
B : numerical value allocated by the sub-authority to the registered organization (mandatory part of the identifier ; 6 digits)
C : numerical value used by the registered organization (free part ; 6 digits)
D : numerical check digit calculated by the registered organization ; (2 digits)

Check digit computation
The check digit is modular 97 computed on ABC as one number.

Display Requirements:

None

Description of organizations covered by the coding system:

Organization highest level
The Deutscher Industrie -und Handelstag will register at their highest level. Organizations (legal persons, partnerships, sole proprietor-ships and their branch offices) registered in the business register or organizations (legal or natural persons) not registered in the business register.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI syntaxes.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

November 1995

Additional comments:

None

 

 

 

0095

Registration Information

ICD:

0095

Name of coding system:

Hewlett - Packard Company Internal AM Network

Name & address of issuing organisation:

Hewlett - Packard Company
3000 Hanover Street
Palo Alto, CA 94304
USA

Phone +1 415 424 3600
Fax +1 415 424 3632

Structure of code:

1) Format includes 2 fields :
First field = ICD
2) Second field = Domain specific part

Display Requirements:

None, except that all fields are left justified

Description of organizations covered by the coding system:

Hewlett - Packard site ATM networks. This encompasses Hewlett - Packard sites throughout the world.

Notes on use of the code:

The ICD will also form part of the Initial Domain part of the OSI network addressing and naming tree as specified in Addendum 2 to ISO 8348

Sponsoring authority:

American National Standards Institute (ANSI) - USA

Date of issue of ICD:

December 1995

Additional comments:

None

 

 

 

0096

Registration Information

ICD:

0096

Name of coding system:

DANISH CHAMBER OF COMMERCE Scheme
(EDIRA compliant)

Name & address of issuing organisation:

Danish Chamber of Commerce
Boerson
DK 1217 Copenhagen
Contact person: Mr Vagn JENSEN
Tel : + 45 33 95 05 00
Fax : + 45 33 32 52 16

Structure of code:

Structure of EDI identifier
Character repertoire
The EDI identifier consists of digits only.
The identifier has a fixed length. No separators are required.
Structure : [123] [123456] [123456] [12]
17
< >
A B C D
A : numerical value allocated by the RA to the regional sub-authority (3 digits)
B : numerical value allocated by the sub-authority to the registered organization (mandatory part of the identifier ; 6 digits)
C : numerical value used by the registered organization (free part ; 6 digits)
D : numerical check digit calculated by the registered organization ; (2 digits)
Check digit computation
The check digit is modular 97 computed on ABC as one number.

Display Requirements:

None

Description of organizations covered by the coding system:

Organization highest level
The Danish Chamber of Commerce & Industry will register at the highest level: Organizations (legal persons, partnerships, sole proprietor-ships and their branch offices) registered in the business register or organizations (legal or natural persons) not registered in the business register.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI syntaxes.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

November 1995

Additional comments:

Originally allocated 0092 but this conflicted with UN/ECE code

 

 

 

0097

Registration Information

ICD:

0097

Name of coding system:

FTI - Ediforum Italia
(EDIRA compliant)

Name & address of issuing organisation:

FTI - Ediforum Italia
Viale Lazio, 21
20135 Milano - ITALY
Contact person: Mr Giorgio PACIFICI
Tel : + 39 2 545 61 20
Fax : + 39 2 551 35 44
E-mail : FTI@mbox.cosi.it

Structure of code:

Structure of EDI identifier
Character repertoire
The EDI identifier consists of digits only.
The identifier has a fixed length. No separators are required.
Structure : [1234567] [123] [1] [12345]
min 11- max 16
< >
A B C D
A : numerical value (7 digits) assigned by Uffico Provinciale IVA (local branch of Ministry of Finance);
B : numerical value a (3 digits) identifying the County;
C : numerical check digit (1 digit);
D : optional numerical value (up to 5 digits0 used by the registerd organization (free part).

Check digit computation
The check digit algorithm is the one published in the Gazzetta Ufficiale no 345 of December 29, 1976.

Display Requirements:

None

Description of organizations covered by the coding system:

FTI - Ediforum Italia will register at their highest level.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI syntaxes.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

February 1996

Additional comments:

None

 

 

 

0098

Registration Information

ICD:

0098

Name of coding system:

CHAMBER OF COMMERCE TEL AVIV-JAFFA Scheme
(EDIRA compliant)

Name & address of issuing organisation:

Chamber of Commerce Tel Aviv-Jaffa
84 Hahashmonaim Street
Tel Aviv 67011, ISRAEL

Contact person: Mr Zvi AMIT, General Manager
Tel : +972 3 563 1010
Fax : +972 3 561 9025

Structure of code:

Structure of EDI identifier
Character repertoire
The EDI identifier consists of digits only.
The identifier has a fixed length. No separators are required.
Structure : [123] [123456] [123456] [12]
17
< >
A B C D
A : numerical value allocated by the RA to the regional sub-authority (3 digits)
B : numerical value allocated by the sub-authority to the registered organization (mandatory part of the identifier ; 6 digits)
C : numerical value used by the registered organization (free part ; 6 digits)
D : numerical check digit calculated by the registered organization ; (2 digits)

Check digit computation
The check digit is modular 97 computed on ABC as one number.

Display Requirements:

None

Description of organizations covered by the coding system:

Organization highest level
The Chamber of Commerce Tel Aviv-Jaffa will register at the highest level: Organizations (legal persons, partnerships, sole proprietor-ships and their branch offices) registered in the business register or organizations (legal or natural persons) not registered in the business register.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI syntaxes.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

February 1996

Additional comments:

None

 

 

 

0099

Registration Information

ICD:

0099

Name of coding system:

Siemens Supervisory Systems Network

Name & address of issuing organisation:

Siemens AG, ON S
Ruppert-Mayer-Str. 44
D-81359 Munchen
Germany
Tel: +49 89 722 23555
Fax: +49 89 722 26473

Structure of code:

  1. cccc (ICD)
  2. No check digits as in general the whole message has a checking mechanism

Display Requirements:

None

Description of organizations covered by the coding system:

Any company or organization using Siemens Supervisory Systems and willing to accept Siemens ON Service as their registration authority for the Supervisory Systems Network. This network encompasses companies and organizations around the world.

Notes on use of the code:

The ICD code will form the initial part of OSI Network addressing and naming tree as depicted in Addendum 2 to ISO 8348 (Network layer addressing). These addresses will uniquely identify systems with Siemens Supervisory Systems Network and to the outside world.

Sponsoring authority:

Deutsches Institut fur Normung e.V (DIN)

Date of issue of ICD:

July 1996

Additional comments:

None

 

 

 

0100

Registration Information

ICD:

0100

Name of coding system:

PNG_ICD Scheme

Name & address of issuing organisation:

GPT Limited
Public Networks Group
New Century Park
P O Box 53
Coventry
CV3 1HJ
Tel. 01203-562-000.
(Contact - ‘Strategy/Customer Network Services’).

Structure of code:

  1. ICD (4 characters)
    Organization Code, comprising 4 fields with a total of 10 characters.
  2. No check digits are used in the code.

Display Requirements:

None

Description of organizations covered by the coding system:

Telecommunications organizations worldwide using the PNG_ICD scheme and requiring a globally unique organization code.

Notes on use of the code:

As per annex A & B of ISO 8348.

Sponsoring authority:

DIN (Deutsches Institut fur Normung) NI
Burggrafen Strasse 6
Berlin.

Date of issue of ICD:

September 1996

Additional comments:

None

 

 

 

0101

Registration Information

ICD:

0101

Name of coding system:

South African Code Allocation

Name & address of issuing organisation:

Thawte Consulting
33 Protea Way
Durbanville 7550
South Africa

Structure of code:

  1. Sequence of digits

Display Requirements:

No special formatting, plain text digits

Description of organizations covered by the coding system:

South African companies, close corporations, State entities and other organizations.

Notes on use of the code:

None

Sponsoring authority:

South African Bureau of Standards (SABS)

Date of issue of ICD:

Oct 1996

Additional comments:

None

 

 

 

0102

Registration Information

ICD:

0102

Name of coding system:

HEAG

Name & address of issuing organisation:

Hessische Elektrizitats-AG
Jagertorstrasse 207
64289 Darmstadt
Germany

Technical Contact :
Peter Giesendorf Tel 049 6151 709 2528
Gerd schmidt Tel 049 6151 709 2547
Andreas Prels Tel 049 6151 709 2529

Fax 049 6151 709 2420

Structure of code:

  1. cccc(ICD)
  2. no check digits

Display Requirements:

None

Description of organizations covered by the coding system:

Any company or organization that is part of the HEAG Holding group and all customers.

Notes on use of the code:

None

Sponsoring authority:

Deutsches Institut fur Normung e.V. (DIN)

Date of issue of ICD:

October 1996

Additional comments:

None

 

 

 

0103

Registration Information

ICD:

0103

Name of coding system:

(Reserved for later allocation)

Name & address of issuing organisation:

 

Structure of code:

 

Display Requirements:

 

Description of organizations covered by the coding system:

 

Notes on use of the code:

 

Sponsoring authority:

 

Date of issue of ICD:

 

Additional comments:

 

 

 

 

0104

Registration Information

ICD:

0104

Name of coding system:

BT - ICD Coding System

Name & address of issuing organisation:

Tony Holmes
pp 9.4
207 Old Street
London
EC1V 9NR
Tel : +44 171 250 6981

Structure of code:

  1. 1) Format includes 2 fields:
    First field = ICD (4 decimal digits)
    Second field = Domain specific part
  2. None

Display Requirements:

None - all fields are left justified

Description of organizations covered by the coding system:

The coding system will be used to provide ATM End System Addresses (AESAs) based on ICD format NSAP addresses. These addresses will be used to identify User Network Interfaces to ATM networks as specified by the ATM Forum UNI specifications. BT will use these addresses internally, and to provide customers with non-geographic private AESAs.

Notes on use of the code:

The ICD code will also form part of the Initial Domain Part of OSI Network Addresses as specified in Annex A of ISO/IEC 8348 : 1993

Sponsoring authority:

BSI

Date of issue of ICD:

Dec 96

Additional comments:

None

 

 

 

0105

Registration Information

ICD:

0105

Name of coding system:

Portuguese Chamber of Commerce and Industry Scheme
(EDIRA compliant)

Name & address of issuing organisation:

Portuguese Chamber of Commerce and Industry
Rua das Portas de Santo Antao, 89
PT 1194 Lisboa Codex
Contact person: Mr Antonio REGUENGOS
Tel : +351 1 342 4111
Fax : +351 1 342 4304
E-mail (X.400) c=pt;a=marconi-sva;p=email400;0=acl-ccip;s=drc;0u=drc

Structure of code:

Structure of EDI identifier
Character repertoire
The EDI identifier consists of digits only.
The identifier has a fixed length. No separators are required.
Structure : [123] [123456] [123456] [12]
17
< >
A B C D
A : numerical value allocated by the RA to the regional sub-authority (3 digits)
B : numerical value allocated by the sub-authority to the registered organization (mandatory part of the identifier ; 6 digits)
C : numerical value used by the registered organization (free part ; 6 digits)
D : numerical check digit calculated by the registered organization ; (2 digits)

Check digit computation
The check digit is modular 97 computed on ABC as one number.

Display Requirements:

None

Description of organizations covered by the coding system:

Organization highest level
The Portuguese Chamber of Commerce and Industry will register at the highest level: Organizations (legal persons, partnerships, sole proprietor-ships and their branch offices) registered in the appropriate business registers (state’s Secretary of State or equivalent) or organizations (legal or natural persons) not registered in the business registers.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

January 1997

Additional comments:

None

 

 

 

0106

Registration Information

ICD:

0106

Name of coding system:

Vereniging van Kamers van Koophandel en Fabrieken in Nederland
(Association of Chambers of Commerce and Industry in theNetherlands)
Scheme
(EDIRA compliant)

Name & address of issuing organisation:

Vereniging van Kamers van Koophandel en Fabrieken in Nederland
Watermolenlaan, 1
NL 3447 GT Woeden
Contact person: Drs. G. C. KNOOP
Tel : +31 348 42 69 11
Fax : +31 348 42 12 31

Structure of code:

Structure of EDI identifier
Character repertoire
The EDI identifier consists of digits only.
The identifier has a fixed length. No separators are required.
Structure : [123] [123456] [123456] [12]
17
< >
A B C D
A : numerical value allocated by the RA to the regional sub-authority (3 digits)
B : numerical value allocated by the sub-authority to the registered organization (mandatory part of the identifier ; 6 digits)
C : numerical value used by the registered organization (free part ; 6 digits)
D : numerical check digit calculated by the registered organization ; (2 digits)

Check digit computation
The check digit is modular 97 computed on ABC as one number.

Display Requirements:

None

Description of organizations covered by the coding system:

Organization highest level
Vereniging van Kamers van Koophandel en Fabrieken in Nederland will register at the highest level:

Organizations (legal persons, partnerships, sole proprietor-ships and their branch offices) registered in the appropriate business registers (state’s Secretary of State or equivalent) or organizations (legal or natural persons) not registered in the business registers.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI syntaxes.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

January 1997

Additional comments:

None

 

 

 

0107

Registration Information

ICD:

0107

Name of coding system:

Association of Swedish Chambers of Commerce and Industry
Scheme
(EDIRA compliant)

Name & address of issuing organisation:

Association of Swedish Chambers of Commerce and Industry
P O Box 16050
SE 10321 Stockholm, Sweden
Contact person: Mr Tell HERMANSON
Tel : +46 8 613 1800
Fax : +46 8 411 2432
E-mail : stock@chamber.se

Structure of code:

Structure of EDI identifier
Character repertoire
The EDI identifier consists of digits only.
The identifier has a fixed length. No separators are required.
Structure : [123] [123456] [123456] [12]
17
< >
A B C D
A : numerical value allocated by the RA to the regional sub-authority (3 digits)
B : numerical value allocated by the sub-authority to the registered organization (mandatory part of the identifier ; 6 digits)
C : numerical value used by the registered organization (free part ; 6 digits)
D : numerical check digit calculated by the registered organization ; (2 digits)

Check digit computation
The check digit is modular 97 computed on ABC as one number.

Display Requirements:

None

Description of organizations covered by the coding system:

Organization highest level
Association of Swedish Chambers of Commerce and Industry will register at the highest level: Organizations (legal persons, partnerships, sole proprietor-ships and their branch offices) registered in the appropriate business registers (state’s Secretary of State or equivalent) or organizations (legal or natural persons) not registered in the business registers.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI syntaxes.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

January 1997

Additional comments:

None

 

 

 

0108

Registration Information

ICD:

0108

Name of coding system:

Australian Chambers of Commerce and Industry
Scheme
(EDIRA compliant)

Name & address of issuing organisation:

Australian Chambers of Commerce and Industry
P O Box E 14, Queen Victoria Terrace
AU Canberra ACT 2600, Australia
Contact person: Mr Brent DAVIS
Tel : +61 6 273 23 11
Fax : +61 6 273 31 96

Structure of code:

Structure of EDI identifier
Character repertoire
The EDI identifier consists of digits only.
The identifier has a fixed length. No separators are required.
Structure : [123] [123456] [123456] [12]
17
< >
A B C D
A : numerical value allocated by the RA to the regional sub-authority (3 digits)
B : numerical value allocated by the sub-authority to the registered organization (mandatory part of the identifier ; 6 digits)
C : numerical value used by the registered organization (free part ; 6 digits)
D : numerical check digit calculated by the registered organization ; (2 digits)

Check digit computation
The check digit is modular 97 computed on ABC as one number.

Display Requirements:

None

Description of organizations covered by the coding system:

Organization highest level
Australian Chambers of Commerce and Industry will register at the highest level: Organizations (legal persons, partnerships, sole proprietor-ships and their branch offices) registered in the appropriate business registers (state’s Secretary of State or equivalent) or organizations (legal or natural persons) not registered in the business registers.

Notes on use of the code:

EDIRA recommendations for coding in EDIFACT and other EDI syntaxes.

Sponsoring authority:

Association Francaise de Normalisation : AFNOR

Date of issue of ICD:

January 1997

Additional comments:

None

 

 

 

0109

Registration Information

ICD:

0109

Name of coding system:

BellSouth ICD AESA (ATM End System Address)

Name & address of issuing organisation:

BellSouth Corporation
1155 Peachtree Street NE
Atlanta, GA 30309
Contact : Robert V. Epley
Tel : + 404-332-2216
Fax : + 404-420-8477

Structure of code:

Field #bytes Name Notes
1 1 Authority and Format Identifier =0x47
2 2 ICD
3 10 Higher Order Domain Specific Part BellSouth administered
4 6 End System Identifier End user field
5 1 Selector End user field

This structure conforms to the ICD AESA specified in User-Network (UNI) Specification Version 3.1 and ATM User-Network Interface (UNI) Signalling Specification Version 4.0 (af-sig-0061.000). Both by the ATM Forum.

Display Requirements:

None

Description of organizations covered by the coding system:

Any BellSouth customer (individual or company) needing an ATM address or block of ATM addresses, initially in the southern USA, but possibly worldwide. These addresses should be reachable by non-BellSouth ATM users via interconnecting ATM carriers.

Notes on use of the code:

Use to form globally unique BellSouth ICD ATM End System Addresses (AESAs)

Sponsoring authority:

American National Standards Institute (ANSI) - USA

Date of issue of ICD:

January 1997

Additional comments:

None

 

 

 

0110

Registration Information

ICD:

0110

Name of coding system:

Bell Atlantic

Name & address of issuing organisation:

Bell Atlantic
1310 N. Courthouse Rd.
3rd Floor
Arlington, VA 22201
Tel : +703-974-1510
Fax : +703-974-0616

Structure of code:

Format includes 2 fields :
First field = ICD
Second field = Domain Specific Part

Display Requirements:

None, except that all fields are left justified

Description of organizations covered by the coding system:

Any organization or company that utilizes Bell Atlantic’s ATM-based services (e.g. Cell Relay Service). As a service provider Bell Atlantic wishes to assign globally unique addresses to its customers.

Notes on use of the code:

The ICD Code will also form part of the Initial Domain Part of the OSI network addressing as specified in Addendum 2 to ISO 8348.

Sponsoring authority:

American National Standards Institute (ANSI) - USA

Date of issue of ICD:

January 1997

Additional comments:

None

 

 

 

0111

Registration Information

ICD:

0111

Name of coding system:

Object Identifiers

Name & address of issuing organisation:

Institute of Electrical and Electronics Engineers
PO Box 1331
445 Hoes Lane
Piscataway, NJ 08855
USA

Structure of code:

SMPTE 298M Universal Labels for Unique Identification of Digital Data an ISO/ITU based identifier hierarchy registration system.

Display Requirements:

None

Description of organizations covered by the coding system:

IEEE, including RAC (registration authority committee) and other sub-entities

Notes on use of the code:

Primary application is SMPTE 298M Universal Labels. Other applications may also be supported.

Sponsoring authority:

American National Standards Institute (ANSI)

Date of issue of ICD:

May 1997

Additional comments:

None

 

 

 

0112

Registration Information

ICD:

0112

Name of coding system:

ISO register for Standards producing Organizations

Name & address of issuing organisation:

International Organization for Standardization (ISO)
1 rue de Varembe
Case Postale 56
CH 1211 Geneve 20
SWITZERLAND

Structure of code:

  1. Numeric sequential

Display Requirements:

None

Description of organizations covered by the coding system:

Any organization, at its highest level, producing standards that need to be referenced by a Technical Committee or other body of ISO or of another international organization working in the area of standardization.

Notes on use of the code:

None

Sponsoring authority:

Association Francaise de Normalisation (AFNOR)

Date of issue of ICD:

May 1997/Amended May 1999

Additional comments:

This system is intended to be used among others by TC 184 for referencing standard producing bodies within the components library standards.

 

 

 

0113

Registration Information

ICD:

0113

Name of coding system:

OriginNet

Name & address of issuing organisation:

Origin BV
Groenewoudse weg 1
5621 BA Eindhoven
The Netherlands

Tel : +31 4027 87295
Fax : +31 4027 89081

Structure of code:

Format includes 2 fields
First field : ICD
Second field : Domain Specific Part

Display Requirements:

None, except all fields left justified

Description of organizations covered by the coding system:

Any organization or company that utilizes Origin’s ATM based services. As a service provider Origin wishes to be able to assign unique addresses to its customers.

Notes on use of the code:

The ICD code will also form part of the Initial Domain Part of the OSI network addressing as specified in addendum 2 to ISO 8348.

Sponsoring authority:

NNI (Nederlands Normalisatie Instituut)

Date of issue of ICD:

May 1997

Additional comments:

None

 

 

 

0114

Registration Information

ICD:

0114

Name of coding system:

Check Point Software Technologies

Name & address of issuing organisation:

Check Point Software Technologies Ltd
3A Jabotinski st. Diamond Tower
Ramat-Gan 52520
ISRAEL

Tel : +972 3613 1833
Fax : +972 3575 9256

Structure of code:

  1. Format includes 3 fields:
    First field : ICD, 4 decimal digits
    Second field : Organization Code, 1-14 characters
    Third field : Organization Name, up to 150 characters
  2. No check digits

Display Requirements:

None, except that all fields are left justified

Description of organizations covered by the coding system:

Check Point Software Technologies subdivisions and customers

Notes on use of the code:

The ICD will also form part of the Initial Domain part of the OSI network addressing and naming tree as specified in Addendum 2 to ISO 8349

Sponsoring authority:

Standards Institution of Israel (SII)

Date of issue of ICD:

June 97

Additional comments:

None

 

 

 

0115

Registration Information

ICD:

0115

Name of coding system:

Pacific Bell Data Communications Network

Name & address of issuing organisation:

Pacific Bell
Broadband Strategy and Engineering
2600 Camino Ramon, Room 1S200BB
San Ramon, CA 94583
USA

Phone : +510-823-3578
Fax : +520-867-1405

Structure of code:

An OSI network address, which consists of the IDP, with subfields AFI and ICD, followed by the Domain Specific Part. No check digits are used.

Display Requirements:

None

Description of organizations covered by the coding system:

Any organization or company that participates in the Pacific Bell Data Communications Network.

Notes on use of the code:

The ICD code will also form the Initial Domain Part of the OSI network addressing and naming tree as specified in ISO 8348.

Sponsoring authority:

American National Standards Institute (ANSI)- USA

Date of issue of ICD:

June 97

Additional comments:

None

 

 

 

0116

Registration Information

ICD:

0116

Name of coding system:

PSS Object Identifiers

Name & address of issuing organisation:

PSS (Postal Security Services)
c/o Finland Post Ltd
Products
Electronic Messaging
P.O. Box 702
FIN-00100 POSTI
FINLAND

Tel : +358 204 511
Fax : +358 204 4545

Structure of code:

  1. As defined in ISO 6523, clause 3.1
  2. Check digits, none

Display Requirements:

As defined in ISO 6523, clause 4.2

Description of organizations covered by the coding system:

All member organizations of PSS. Currently Finland Post Ltd., Norway Post, Post Denmark, Sweden Post Ltd., PostGEM and their associated companies.

Notes on use of the code:

A) In the SIO the organization name will normally be omitted

B) The code is primarily intended for the registration of Object Identifiers according to ISO/IEC 8824:
Level 1: iso (1)
Level 2: identified organization (3)
Level 3: PSS (xxxx)
Level 4 and higher: defined by PSS conventions

Sponsoring authority:

Finish Standards Association, SFS

Date of issue of ICD:

July 1997

Additional comments:

PSS (Postal Security Services) is a grouping of Postal companies offering security services in telecommunication. Finland Post Ltd. Acts as a co-ordinator of registration of common OIDs.

 

 

 

0117

Registration Information

ICD:

0117

Name of coding system:

STENTOR-ICD CODING SYSTEM

Name & address of issuing organisation:

B. Sambasivan
Stentor Resource Centre Inc.
Room 480, 160 Elgin St.
Ottowa, Ontario K1G 3JA
Canada
Tel.# + 1 613 781 7458
Fax.# + 1 613 781 6454

Structure of code:

  1. Format includes 2 fields.
    First field - ICD(4 decimal digital)
    Second field - Domain Specific Part
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

The coding system will be used within Stentor’s ATM network to identify ICD NSAP end points.

Notes on use of the code:

The ICD code will be used to form the Initial Domain part of the OSI Network Address as specified in Annex A of ISO/IEC 8348:1993

Sponsoring authority:

Standards Council of Canada (SCC)

Date of issue of ICD:

August 97

Additional comments:

None

 

 

 

0118

Registration Information

ICD:

0118

Name of coding system:

ATM-Network ZN’96

Name & address of issuing organisation:

Deutsche Telekom AG
AM Kavalleriesand 3
64295 Darmstadt

Structure of code:

ICD Format
(4 characters)

Display Requirements:

--none--

Description of organizations covered by the coding system:

--none at present time--

Notes on use of the code:

--none--

Sponsoring authority:

DIN-NI

Date of issue of ICD:

August 97

Additional comments:

--none--

 

 

 

0119

Registration Information

ICD:

0119

Name of coding system:

MCI / OSI Network

Name & address of issuing organisation:

MCI Telecommunications Corporation
Technical Standards Management
Dept. 1225/107
2400 N. Glenville Dr.
Richardson, TX 75082
USA

Phone +1.972.918.5630
Fax +1.972.918.6038

Structure of code:

Three fields
First Field = ICD
Second Field = Organization Code, 1-14 digits
Third Field = Organization Name, up to 250 digits

Display Requirements:

None, except that all fields are left justified.

Description of organizations covered by the coding system:

Any organization in a MCI / OSI networking environment. This program encompasses organizations throughout the world.

Notes on use of the code:

The ICD code will also form the Initial Domain Part of the OSI network addressing and naming tree as specified in Addendum 2 to ISO 8348.

Sponsoring authority:

American National Standards Institute (ANSI) - USA

Date of issue of ICD:

August 1997

Additional comments:

 

 

 

 

0120

Registration Information

ICD:

0120

Name of coding system:

Advantis

Name & address of issuing organisation:

Advantis
Charles M. Reiss
231 N. Martingdale Rd
Schaumbur, Ill, USA
60173-2254
Phone : 847-240-8504
Fax : 847-240-3864

Structure of code:

The format includes three fields:
First field: ICD, 4 digits
Second field: Organization code, 1-14 digits
Third field: Organizational name up to 250 digits

Display Requirements:

None

Description of organizations covered by the coding system:

This ICD structure will be used for ATM customers of Advantis. This would also be used for all managed devices provided by Advantis around the world in the LAN, Campus and WAN.

Notes on use of the code:

None

Sponsoring authority:

American National Standards Institute (ANSI) - USA

Date of issue of ICD:

October 97

Additional comments:

This ICD number will be used to identify ATM devices that are attached to our ATM service. Typically this world wide ATM service would be offered to Fortune 100 customers, like Sears, who want a managed ATM solution or who require full ATM campus to campus outsourcing. The addressing components would include Host or otherdevice, LAN, Campus, and global WAN nodes.

 

 

 

0121

Registration Information

ICD:

0121

Name of coding system:

Affable Software Data Interchange Codes

Name & address of issuing organisation:

Affable Software Corporation
6239 Thome Avenue
Burnaby, British Columbia
Canada- V3N 2V2

Contact : Eric Kolotyluk
Tel : +1-604 522-1201

Structure of code:

  1. format: XXXX/AFC
    example: 0000/AFC
  2. none

Display Requirements:

None

Description of organizations covered by the coding system:

Organizations using Affable Software applications and data standards

Notes on use of the code:

The ICD code will form the initial part of the naming tree for applications and data standards supported by Affable Software forming the initial part of the OBJECT IDENTIFIER tree.

Sponsoring authority:

Standards Council of Canada
45 O’Connor Street- Suite 1200
Ottawa, Ontario K1P 6N7
Canada

Tel + 1-613-238-3222
Fax: +1-613-395-4564

Date of issue of ICD:

Feb 1998

Additional comments:

None

 

 

 

0122

Registration Information

ICD:

0122

Name of coding system:

BB-DATA GmbH

Name & address of issuing organisation:

BB-DATA GmbH
Brunnestrasse 11
13355 Berlin
Germany

Contact : Dirk Haegebarth
Tel : +49 30 2455 4353
Fax ; +49 30 2455 7201

Structure of code:

cccc(ICD)

Display Requirements:

None

Description of organizations covered by the coding system:

The BB-Data is a Service Provider for the Bankgesellschaft Berlin and subsidiary companies

Notes on use of the code:

None

Sponsoring authority:

DIN-NI

Date of issue of ICD:

Feb 98

Additional comments:

None

 

 

 

0123

Registration Information

ICD:

0123

Name of coding system:

BASF Company ATM-Network

Name & address of issuing organisation:

BASF Computer Services GmbH
Carl-Bosch-Str. 38
67056 Ludwigshafen
Germany

(Contact: BCS/NET Tel. + 49621 60 49323)

Structure of code:

  1. ICD (International Code Designator)
  2. Organization code, comprising 4 fields with a total of10 characters

Display Requirements:

None

Description of organizations covered by the coding system:

Any organization part of the BASF Company requiring a unique organization code

Notes on use of the code:

As specified in ISO 8348

Sponsoring authority:

DIN (Deutsches Institut fur Norung e.V.)
Burggrafenstr. 6, D 10787 Berlin

Date of issue of ICD:

Feb 98

Additional comments:

None

 

 

 

0124

Registration Information

ICD:

0124

Name of coding system:

IOTA- Identifiers for Organizations for Telecommunications Addressing using the ICD system format defined in ISO/IEC 8348

Name & address of issuing organisation:

DISC
British Standards Institution
389 Chiswick High Road
London W4 4AL
UK

Structure of code:

1) The four digit fixed length

2) A fixed length six digit number in the range 000001 to 999999. Values will be allocated sequentially by the Issuing Organization starting at 001001. The range 000001 to 001000 is reserved in case it is required for special purposes.

Display Requirements:

The organization identifier is intended for use as a fixed length six digit number padded to length where necessary with non significant zeros. However, it may be used as appropriate for the particular application. In particular it may be used as a binary value omitting numerically non significant zeros.

Description of organizations covered by the coding system:

Any organization requiring an identifier for use in constructing telecommunications addresses, e.g. ATM addresses, in accordance with the ISO 6523 ICD Format as specified in ISO/IEC 8348. Identifiers may also be used for other purposes including the creation of object identifier component values using the identified-organization as specified in ISO/IEC 8824-1.

Notes on use of the code:

The identifiers issued under this scheme are specifically intended for use as a component in the construction of telecommunications addresses using the ISO 6523 Format as specified in ISO/IEC 8348. However, at the discretion of the user they may be employed for other purposes including the formation of other types of telecommunications addresses and OSI object identifiers.

Sponsoring authority:

DIN (Deutsches Institut fur Normung) NI
Burggrafenstrasse 6
Berlin

Date of issue of ICD:

April 98

Additional comments:

None

 

 

 

0125

Registration Information

ICD:

0125

Name of coding system:

Henkel Corporate Network (H-Net)

Name & address of issuing organisation:

Henkel KgaA
Dep: SIS/BC-Networks
40191 Dusseldorf
Germany

Contact:
Christopher Heidler Uwe Wirtz
Tel: + 49 211 797 9400 Tel: +49 211 797 5500
Fax: + 49 211 798 19400 Fax: +49 211 798 1110

Structure of code:

  1. ICD (4 characters)
  2. Organization code, comprising 4 fields with a total of 10 characters

No check digits are used in the code

Display Requirements:

None

Description of organizations covered by the coding system:

World-wide Henkel affiliated companies using the Henkel Corporate Network (H-Net) and requiring a globally unique organization code

Notes on use of the code:

As specified in ISO 8348

Sponsoring authority:

DIN (Deutsches Institut fur Normung) NI
Buggrafenstrasse 6
Berlin
Germany

Date of issue of ICD:

March 98

Additional comments:

None

 

 

 

0126

Registration Information

ICD:

0126

Name of coding system:

GTE/OSI Network

Name & address of issuing organisation:

GTE
Industry Standards
HQW02J85
700 Hidden Ridge
Irving, TX 75038
USA

Phone: + 972 718 6291
Fax: + 972 718 4393

Structure of code:

  1. ICD
  2. Organization Code, 1-14 characters
  3. Organization name, up to 250 characters

Display Requirements:

None, except all fields are left justified

Description of organizations covered by the coding system:

Any organizations in a GTE/OSI networking environment. This program encompasses organizations throughout the world.

Notes on use of the code:

The ICD will also form the Initial Domain part of the OSI network addressing and naming tree as specified in Addendum 2 to ISO 8348.

Sponsoring authority:

American National Standards Institute (ANSI)- USA

Date of issue of ICD:

May 1998

Additional comments:

None

 

 

 

0127

Registration Information

ICD:

0127

Name of coding system:

Dresdner Bank Corporate Network

Name & address of issuing organisation:

Dresdner Bank AG
IT-Kommunikationssysteme

Windmuehlstr. 14
60329 Frankfurt am Main
Germany

Contact : Peter Radig
Tel : + 49 69 263 7243
Fax : + 49 69 263 5510
Email : Peter.Radig@Dresdner-Bank.com

Structure of code:

ICD (4 characters)

Display Requirements:

None

Description of organizations covered by the coding system:

  1. All national and international offices, branches and subsidiaries of the Dresdner Bank Group.
  2. All customers of the Dresdner Bank Corporate Network

Notes on use of the code:

None

Sponsoring authority:

Deutsches Institut fur Normung e.V. (DIN)

Date of issue of ICD:

July 1998

Additional comments:

None

 

 

 

0128

Registration Information

ICD:

0128

Name of coding system:

BNCR (Telekurs Banken Clearing Number)

Name & address of issuing organisation:

Telekurs AG
Hardturmstrasse 201
CH – 8021 Zurich
Switzerland
Tel +41.1.279.2111

Structure of code:

  1. n..6
  2. Minimum of 4 numeric characters

Display Requirements:

None

Description of organizations covered by the coding system:

Swiss banking institutions

Notes on use of the code:

None

Sponsoring authority:

S.W.I.F.T. sc (Society for Worldwide Interbank Financial Telecommunication sc)

Date of issue of ICD:

July 98

Additional comments:

None

 

 

 

0129

Registration Information

ICD:

0129

Name of coding system:

BPI (Telekurs Business Partner Identification)

Name & address of issuing organisation:

Telekurs AG
Hardturmstrasse 201
CH – 8021 Zurich
Switzerland
Tel +41.1.279.2111

Structure of code:

  1. an..6
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

Swiss non-banking institutions

Notes on use of the code:

None

Sponsoring authority:

S.W.I.F.T. sc (Society for Worldwide Interbank Financial Telecommunication sc)

Date of issue of ICD:

July 1998

Additional comments:

None

 

 

 

0130

Registration Information

ICD:

0130

Name of coding system:

Directorates of the European Commission

Name & address of issuing organisation:

European Commission
Information Directorate
Data Transmission Service
Rue de la Loi, 200
B-1049 Brussels
Belgium

Structure of code:

  1. ICD 4 digits
  2. None

Display Requirements:

None

Description of organizations covered by the coding system:

General Directorates of the European Commission

Notes on use of the code:

The code will be used for the generation of ATM network addresses in the context of EC’s private ATM network, interconnecting all of EC’s directorates across Europe

Sponsoring authority:

IBN – Belgium

Date of issue of ICD:

August 98

Additional comments:

None

 

 

 

0131

Registration Information

ICD:

0131

Name of coding system:

Code for the Identification of National Organizations

Name & address of issuing organisation:

China National Organization Code Registration Authority
Center (CNRAC)
No 46. East Door, Dewai Yu Zhong Xi Li
Xicheng District
Beijing
P.R. of China, 100029

Tel. + 86 10 6202 4549
Fax. + 86 10 6202 4513

Structure of code:

  1. ICD (International Code Designator)
  2. Organization Code, comprising 2 fields with a total of 9 characters. 8 number or character body code and 1 number or character check code.

Display Requirements:

None

Description of organizations covered by the coding system:

Any organization requiring an identifier for use in informationized management of Nation.

Notes on use of the code:

None

Sponsoring authority:

China State Bureau of Quality & Technical Supervision (CSBTS)
4 Zhicun Road, Haidian District, P.O. Box 8010, Beijing,
China, 100088
ISO/IEC China National Committee
Fax. +8610 6203 3737

Date of issue of ICD:

Sept 98

Additional comments:

None

 

 

 

0132

Registration Information

ICD:

0132

Name of coding system:

Certicom Object Identifiers

Name & address of issuing organisation:

Certicom Corp
Suite 1050
1400 Fashion Island Blvd
San Mateo, CA 94404
U.S.A.

Tel : 650 312 7960
Fax : 650 312 7969

Structure of code:

Two fields :
First field – ICD
Second field - Sequence of digits

Display Requirements:

None

Description of organizations covered by the coding system:

Certicom, its subdivisions, its customers, and any organiztion using Certicom’s cryptographic services and products. Such customers and organizations include; domestic and foreign companies, state entities, and standards groups.

Notes on use of the code:

The ICD is primarily intended for registration of Object Identifiers in accordance with ISO/IEC 8824 (ASN.1) to be used for the registration of the following:
a) Application layer protocols
b) Cryptographic protocols
c) Data formats of keying information
d) Information objects pertaining to data exchange

The OID structure and the inclusion therein of the ICD is as follows:
Level 1: iso (1)
Level 2: identified-organization (3)
Level 3: certicom (xxxx)
Level 4 and higher: Defined by Certicom

Sponsoring authority:

American National Standards Institute (ANSI) - USA

Date of issue of ICD:

November 1998

Additional comments:

The Issuing Organization within Certicom shall be Certicom Research. The contact is John O. Goyo (jgoyo@certicom.com) who may be reached at 905-501-3850

 

 

 

0133

Registration Information

ICD:

0133

Name of coding system:

TC68 OID

Name & address of issuing organisation:

ISO TC68, Banking and Related Financial Services
c/o American Bankers’ Association
1120 Connecticut Ave, N.W.
Washington, DC 20036
USA

Tel : 1- (202) 663 5284
Fax : 1- (202) 828 4540

Structure of code:

  1. Three fields
    First field = ICD
    Second field = Member Country Code, 1-14 characters
    Third field = Number of Standard

Display Requirements:

None

Description of organizations covered by the coding system:

ISO Technical Committee 68 and member bodies

Notes on use of the code:

The ICD code will form the Initial Domain Part of the OSI network addressing and naming tree as specified in Addendum 2 to ISO 8348.

Sponsoring authority:

American National Standards Institute (ANSI)

Date of issue of ICD:

December 1998

Additional comments:

None

 

 

 

0134

Registration Information

ICD:

0134

Name of coding system:

Infonet Services Corporation

Name & address of issuing organisation:

Infonet NV/SA
Av. Louise 350 Box 3
1050 Brussels
Belgium

Attn : Mr Mircea Pisica - Senior System Engineer
E-mail :
Mircia_Pisica@infonet.com
Tel : +322 627 3900
Fax : +322 646 1308

Structure of code:

  1. ICD Code- 4 digits
    Organization code - up to 14 characters
    Organization name - up to 250 characters
  2. No check digits needed

Display Requirements:

None- all fields are left justified

Description of organizations covered by the coding system:

The coding system will be used to provide ATM End System Addresses (AESAs) based on ICD format NSAP addresses. These addresses will be used to identify User Network Interfaces to ATM networks as specified by the ATM forum UNI specifications. Infonet will use these addresses internally, and to provide customers with non-geographic private AESAs.

Notes on use of the code:

The ICD code forms the initial part of the OSI network addressing and tree as depicted in Addendum 2 of ISO 8348 (Network Layer Addressing). Infonet intends to use these addresses to uniquely identify systems within INFONET and to the outside world.

Sponsoring authority:

Institut Belge de Normalisation (IBN)- Belgium

Date of issue of ICD:

January 1999

Additional comments:

None

 

 

 

0135

Registration Information

ICD:

0135

Name of coding system:

SIA Object Identifiers

Name & address of issuing organisation:

SIA-Società Interbancaria per l’Automazione S.p.A.
Viale Certosa, 218
I-20156 Milano, ITALIA

Tel. +39-02-3005.1
Fax: +39-02-38003333

Structure of code:

First field: ICD : 4 digits
Second field: sequence of digits

Display Requirements:

None

Description of organizations covered by the coding system:

SIA is a company owned (as of Feb 99) by Bank of Italy (Italy’s Central Bank) and the Association of Italian Bankers (ABI), plus a number of other banks. SIA’s mission is that of delivering infrastructural data transportation security and processing services to the whole community of Italian banksand financial companies. SIA runs the Italian national interbank network and the gateway to the SWIFT international network; SIA develops and manages the applications and systems supporting electronic financial markets for the negotiation of government bonds and derivatives. SIA also runs the Root CA (ISO 9594-8 certification authority) within the Italian bankers’ public key infrastructure (PKI). For more information please visit SIA’s web site at http://www.sia.it

Notes on use of the code:

The code is primarily intended for the registration of Object Identifiers according to ISO 8824/8825:
Level 1: iso (1)
Level 2: identified-organization (3)
Level 3: SIA SpA (0135)
Level 4: and higher: (defined by SIA conventions)

The contact person is Ing. Adriano Santoni (email:
santoni@sia.it)

Sponsoring authority:

UNI, Ente Nazionale Italiano di Unificazione
Via Battistotti Sassi 11/B, Milan I-20133, Italy
Tel: +39-02-70024-1
Fax: +39-02-70106149
Contact person: Mr. Mike Ganoza
(e-mail: mike.ganoza@uni.unicei.it)

Date of issue of ICD:

March 1999

Additional comments:

None

 

 

 

0136

Registration Information

ICD:

0136

Name of coding system:

Cable & Wireless Global ATM End-System Address Plan

Name & address of issuing organisation:

Cable & Wireless Global Business Inc.
8230 Boon Boulevard
Vienna , Virginia 22182
USA

Structure of code:

  1. ICD 4 digits

Display Requirements:

None

Description of organizations covered by the coding system:

Cable & Wireless global group of companies (including but not limited to: CWC in the UK, CWUSA in the USA, Hong Kong Telecom in Hong Kong, CW OPTUS in Australia)

Notes on use of the code:

The code will be used in the provision of a consistent global plan for the generation of ATM AESA addresses across the Cable & Wireless group of companies. The plan will be utilised internal to Cable & Wireless and to provide customers with non-geographic addresses.

Sponsoring authority:

ANSI

Date of issue of ICD:

June 1999

Additional comments:

None

 

 

 

0137

Registration Information

ICD:

0137

Name of coding system:

Global AESA scheme

Name & address of issuing organisation:

Global One
Park Atrium
Rue des Colonies, 11
B-1000 Brussels
Belgium

Tel + 322 545 2000
Fax + 322 545 2005

Intended purpose
/application area:

Construct and Administer AESAs
Routing of ATM switched connections

Structure of code:

1) Field
1 Authority and Format Identifier
2 ICD
3 Higher Order Domain Specific Part
Assigned by Global One

2)

Display Requirements:

As specified by ATM Forum User Specification Version 4.0 & 3.1

Character Repertoire:

As specified by ATM Forum User Specification Version 4.0 & 3.1

Language(s) used:

English

Supports Organization Parts:

Upon agreement or per request of the specific organisation

Organization Identifier reuse:

The minimum period elapsed will depend on the terms of agreement with the specific organisation and will be determined taking into account the technical, administrative and regulatory issues. It is expected to vary from an hour up to six months.

Description of organizations covered by the coding system:

Any organisation or company that utilises Global One's ATM Services worldwide
Global one national and international switching equipment

Notes on use of the code:

Use to from globally unique Global One ICD AESAs

Sponsoring authority:

Association Frances de Normalisation (AFNOR) - FRANCE

Date of issue of ICD:

December 1999

Additional comments:

None

 

 

0138

Registration Information

ICD:

0138

Name of coding system:

France Telecom ATM End System Address Plan

Name & address of issuing organisation:

France Telecom
BRX/DAP/AFC
6 place d'Alleray
75505 Paris Cedex 15
France

Tel + 331 4444 2775
Fax + 331 4444 2437
e-mail : alain.bidron@francetelecom.fr

Intended purpose
/application area:

The coding system will be used to provide ATM End System Addresses based on ICD format NSAP addresses. These addresses will be used to uniquely identify User Network Interfaces to ATM networks as specified by the ATM Forum UNI specifications. France telecom will also use these addresses Internally, and to provide worldwide customers with non- Geographic private AESAs. These global addresses should be Reachable by non-France Telecom ATM users via Interconnecting ATM carriers.

Structure of code:

Field #bytes Name
1 1 Authority and Format Identifier (0x47)
2 2 ICD
3 10 Higher Order Domain Specific Part
(administered by France Telecom)
4 6 End System Identifier (End user field)
5 1 Selector (End user field)

Display Requirements:

None- all fields are left justified

Character Repertoire:

Fields are binary encoded.
For a field of length N, the range will be from 0 to 2N-1

Language(s) used:

English

Supports Organization Parts:

No

Organization Identifier reuse:

Technically one hour; administratively, three weeks ageing period

Description of organizations covered by the coding system:

These addresses will be used to uniquely identify User Network Interfaces to ATM networks as specified by ATM Forum UNI specifications. France Telecom will also use these addresses internally, and to provide worldwide customers with non-geographic private AESAs.

Notes on use of the code:

The ICD Code will also form part of the Initial Domain Part of the OSI network addressing as specified in Addendum2 to ISO 8348

Sponsoring authority:

Association Frances de Normalisation (AFNOR) - FRANCE

Date of issue of ICD:

December 1999

Additional comments:

None

 

 

0139

Registration Information

ICD:

0139

Name of coding system:

Savvis Communications AESA

Name & address of issuing organisation:

Savvis Communications
Contact: Gary Rubel
717 Office Parkway
St Louis, MO 63141-7115

Tel: - +314-468-4104 (Direct),
+314-468-7030 (Main)
Fax: - +314-468-7050

Intended purpose
/application area:

Global Addressing of Savvis ATM Switches and any direct customer ATM networks for implementation of PNNI.

Structure of code:

First Field = ICD (0x47)
Second Field = Domain Specific Part (0x124)
Third Field = Organisation ID (3 bytes)
Fourth Field = Domain Specific Part (7 bytes)

The Domain Specific will be used to for assigning ATM Addresses according to ATM Forum UNI3.1/4.0 and PNNI 1.0 Specifications

Display Requirements:

None

Character Repertoire:

 

Language(s) used:

 

Supports Organization Parts:

 

Organization Identifier reuse:

 

Description of organizations covered by the coding system:

Any Savvis ATM network element needing ATM addresses as well as customer devices requiring AESAs. Savvis has network POPs in the US and Europe and will be expanding to Asia.

Notes on use of the code:

Used to form a globally unique Savvis ICD ATM End System Address

Sponsoring authority:

American National Standards Institute (ANSI) - USA

Date of issue of ICD:

January 2000

Additional comments:

None

 

 

0140

Registration Information

ICD:

0140

Name of coding system:

Toshiba Organizations, Partners, And Suppliers’ (TOPAS) Code

Name & address of issuing organisation:

Toshiba Corporation, 1-1 Shibaura, 1-Chome, Minato-Ku, Tokyo
105-8001, Japan.
Request for a TOPAS Code
Attention to: TOPAS Administration, Technology Planning Division
Person Responsible:
Dr. Akinobu Kasami
Corporate Executive Vice President and Director
Contact Person for this application and technical issues:
Mr. Hiroshi Murayama
Human Interface Laboratory, Toshiba Corporate Research and Development Centre,
Address: 1, Komukai Toshiba-cho, Saiwai-ku, Kawasaki-shi, 212-8582, Japan
Email:
hiroshi.murayama@toshiba.co.jp
TEL :(+81) 44-549-2397
FAX : (+81) 44-520-1308

Intended purpose
/application area:

The purpose of this coding system is to identify organizations world-wide, that have business or technical transactions with Toshiba Corporation, in terms of ISO-13584 Parts Library standard based electronic catalogue interchange service. The interchange is not limited to those between a member organization and Toshiba Corporation. Interchanges between member organizations based on the organization identifier of this coding system are also in scope. Reference to this organization identification code in other business transactions is also allowed

Structure of code:

1. ICD 4 digits
2. Organization Identifier
3. Organization Part Identifier
4. OPIS -----1 character

1) Up to 35 characters

2) No check character required

Display Requirements:

No display requirement

Character Repertoire:

ISO10646: cells 00 to 7F of row 00 of plane 00 of group 00 i.e., identical to "EXPRESS characters set" defined in ISO-10303 -11 "The EXPRESS Language Reference Manual", section 7.1

Language(s) used:

English, Japanese, French

Supports Organization Parts:

It supports organization parts

Organization Identifier reuse:

1 day after the withdrawal

Description of organizations covered by the coding system:

  1. Organizations in the world that have business or technical transactions with Toshiba Corporation and registered as member organizations of the coding system for ISO-13584 Parts Library standard based electronic data interchange
  2. Toshiba Corporation, and its affiliates world-wide

Notes on use of the code:

Reference to this organization identifier in other business transactions is also possible, provided the organizations concerned are registered as members of the coding system

Sponsoring authority:

Sponsoring: ISO TC184/SC4 Secretariat is at:
National Institute Of Standards and Technology
100 Bureau Drive, Gaithersburg, MD 20899-0001,USA.
For this application contact to:
SC4 Chair: Mr. Richard Wandmacher
adr: General Motors, Mail Code: 483-616-705
16 East Judson Street, Pontiac, MI 48232-2205,USA
dick.wandmacher@gm.com <dick.wandmacher@gm.com>

Date of issue of ICD:

January 2000

Additional comments:

Alternate names : TOPAS may be construed as "Toshiba Organizations, Partners, and Suppliers", preferred to be pronounces as "topaz [topa:z]"

 

 

0141

Registration Information

ICD:

141

Name of coding system:

NATO Commercial and Government Entity system

Name & address of issuing organisation:

NATO Group of National Director on Codification (AC/135)
NATO Maintenance and Supply Agency
11 Rue de la Gare
L-8302 Capellen
G. D. Luxembourg
Attn: Secretary to AC/145, LZ-C Programme

Intended purpose
/application area:

To identify all Commerical and Governmental entities that provide material and/or services to the Armed Forces of the NATO nations and several non-NATO nations (Sponsored) around the world.

This information is used by NATO and Sponsored nations’ Logisticians to identify Commercial and Government Entities they deal with. This Information is used by all functions of Logistics support such as Acquisition, Sourcing, EDI, Re-Provisioning, Material Management, etc.

Structure of code:

  1. This code consists of:
  • Three alpha and/or numeric characters prefixed and suffixed by a numeral, for Canada and the United States, or
  • Three alpha and/or numeric characters either prefixed by one significant alpha character and suffixed by one numeral or suffixed by one significant alpha character and prefixed by one numeral for the other user countries/organizations.

2) None

Display Requirements:

None

Character Repertoire:

The NCAGE Code is limited to alphabetic (A-Z) and numeric (0-9) characters. The NCAGE Code is of fixed length.

Language(s) used:

Usually English or French but could be the language of any of the user nations.

Supports Organization Parts:

The NCAGE system does not support identification of organization parts.

Organization Identifier reuse:

NCAGE codes are not reused once assigned.

Description of organizations covered by the coding system:

The following types of organizations/functions are eligible for NCAGE Code assignment; however a NCAGE Code should not be assigned unless it is required:

  • Manufacturing organizations that are obtained.
  • Government or commercial organizations that control the design of items but not necessarily manufacture nor sell them directly.
  • Manufacturing organizations that produce items of industrial production equipment, and whose items are published in industrial plant equipment handbooks.
  • Distributors who are sources of supply in their own country for items produced by manufacturers located in their own or in any foreign country.
  • Government agencies that manufacture items entering the supply system of an individual NATO country or control the design of such items without actually manufacturing them.
  • Manufacturers who supply materials for incorporation into the products of manufacturers who provide drawings of these products.
  • Organizations connected with the development of national or international standards/ specifications or related documents.
  • NATO Production or Logistics Organizations- NPLO- or NATO Agencies who act as design activities and provide standards, specifications or drawings containing information qualified for item identification purpose.
  • Providers of service working in the field of logistics (repair shops, carriers…) but not providing items of production they referenced in their system.

Notes on use of the code:

Determination of the real source for an item of supply is one of the most important prerequisites for proper application of the Uniform System of Item Identification within NATO. It is the source where documentation will be obtained from and its location normally gives advice for codification responsibility. Within the NATO Codification System the term Manufacturer covers the whole range of possible sources of technical data for items entering the supply chains or participating countries. The primary use of manufacturers coding is in ADP operations related to support management programs, such as material management codification, standardization, etc.

Sponsoring authority:

ISO/TC 184/ SC 4

Date of issue of ICD:

March 2000

Additional comments:

Alternate names for scheme -
NCAGE
NATO Code of Manufacturers

 

 

0142

Registration Information

ICD:

0142

Name of coding system:

SECETI Object Identifiers

Name & address of issuing organisation:

Servizi Centralizzati SECETI S.p.A.
Via Zurigo, 3-20147 Milano, ITALY

Tel : +39-02-48310.1
Fax: +39-02-48310206

Intended purpose
/application area:

The function as the ‘Application Centre’ for the Italian National Interbank Network, having been authorized by the Bank of Italy and the Italian Banking Association to operate in that capacity. The scheme is intended for the registration of object identifiers according to ISO 8824 and ISO 8825

Structure of code:

1) First field: ICD : 4 digits

2) Second field: sequence of digits

Display Requirements:

None

Character Repertoire:

 

Language(s) used:

 

Supports Organization Parts:

 

Organization Identifier reuse:

 

Description of organizations covered by the coding system:

SECETI S.p.A.- 100% owned by the Central Institute of Italian Popular Banks- is a leading company fully entitled by the Bank of Italy and the Italian Banking Association to operate as ‘Application Centre’ of the National Interbank Network.

As such, SECETI provides a very extensive range of specialized services to the Italian banks running, for about 200 of them, direct connections to the bank system procedures (payments, check truncation, debit/credit cards processing,…). These services include outsourcing services and, for most of their

corporate customers, high security centralized links to the whole bank system.

SECETI is the Italian leading supplier of specialized software Products which allow banks full accomplishment of both Bank of Italy and European Central Bank norms and regulations monitoring and surveillance.

Web site at http:www.seceti.it

Notes on use of the code:

The code is primarily intended for the registration of Object Identifiers according to ISO 8824/8825

Level 1: ISO (1)

Level 2: identified –organization (3)

Level 3: SECETI S.p.A. (ICD)

Level 4: and higher: (defined by SECETI conventions)

The contact person is Dr. Elvezio Montesarchio

e-mail: elvezio.montesarchio@seceti.it

Sponsoring authority:

UNI, Ente Nazionale Italiano di Unificazione

Via Battistotti Sassi 11/B, Milan I-20133, Italy

Tel: +39-02-70024 399

Fax: +39-02-70106149

Contact person: Mr. Mike Ganoza

(e-mail: mike.ganoza@uni.unicei.it)

Date of issue of ICD:

March 2000

Additional comments:

None

 

 

 

 

01xx

Registration Information

ICD:

 

Name of coding system:

 

Name & address of issuing organisation:

 

Intended purpose
/application area:

 

Structure of code:

1)

2)

Display Requirements:

 

Character Repertoire:

 

Language(s) used:

 

Supports Organization Parts:

 

Organization Identifier reuse:

 

Description of organizations covered by the coding system:

 

Notes on use of the code:

 

Sponsoring authority:

 

Date of issue of ICD:

 

Additional comments: